Données clés
-
Measured variables
O2
-
Measuring range
O2: 0 ... 5 Vol.-% / 0 ... 100 Vol.-%
-
Ambient temperature range
–20 °C ... +60 °C
Domaine d'application
Measuring the oxygen in the process can be quite simple. The TRANSIC100LP is a rugged transmitter that uses tunable diode laser spectroscopy (TDLS) to measure O2 reliably. A technology more common in the world of high-tech analysis is now being used in a field instrument: at an attractive price, easy installation, a long life, low maintenance and suitable for use in explosion-hazardous areas.
Monitoring of inert gas blanketing in tanks and vessels
O2 measurement in process gases
Replacement of extractive paramagnetic oxygen analyzers and electrochemical cells
Ambient air monitoring
Device properties:
O2 transmitter based on high-performance laser spectroscopy (TDLS)
For use in use in explosion-hazardous areas (FM, ATEX and IECEx approvals)
Designed for heavy-duty industrial applications
Compact design and easy to operate
Long-term stability
No moving parts
Avantages
Fast in-situ measurement directly in the process
Easy installation and operation
Self-diagnostics with maintenance display
Low requirements for gas conditioning
Low operating costs: almost no consumables and no purging gas consumption
Rugged: reliable measurement also possible even in contaminated gases
Vidéos
Xpert selection
-
Produits spécialisés
- Conçu pour les applications exigeantes
Excellence technique
Simplicité
Variable

-
Produits simples
- Facile à sélectionner, à installer et à utiliser
Excellence technique
Simplicité
-
Produits standard
- Fiable, robuste et effort de maintenance réduit
Excellence technique
Simplicité
-
Produits haut de gamme
- Hautement fonctionnel et pratique
Excellence technique
Simplicité
-
Produits spécialisés
- Conçu pour les applications exigeantes
Excellence technique
Simplicité
Variable
FLEX selections | Excellence technique | Simplicité |
---|---|---|
Fundamental selection Parfait pour les applications de base |
Excellence technique
|
Simplicité
|
Lean selection Performances optimales pour piloter les applications standards |
Excellence technique
|
Simplicité
|
Extended selection Fonctionnalités avancées pour maximiser vos process |
Excellence technique
|
Simplicité
|
Xpert selection Performances exceptionnelles pour applications exigeantes |
Excellence technique
|
Simplicité
Variable |
-
-
Innovation (IN)
TRANSIC100LP – laser oxygen transmitter
Version anglaise - 01/2025
TRANSIC100LP is the rugged transmitter that uses Tunable Diode Laser Spectroscopy (TDLS) to measure O2 reliably.
Langue:
Anglais
Version:
01/01/2025
Taille du fichier:
3.2 MB
Nom du fichier:
8029960_IN_TRANSIC100LP_en_V3-1_2025.01_EHS.pdf
-
-
-
Solution pour l'industrie (SO)
Solutions for chemicals, petrochemicals and refineries
Version anglaise - 01/2025
Endress+Hauser offers a broad product portfolio of continuous gas analyzers using state-of-the-art technologies.
Langue:
Anglais
Version:
01/01/2025
Taille du fichier:
3.1 MB
Nom du fichier:
8030415_CPR_en_V1-0_2025.01_EHS.pdf
-
-
-
Manuel de mise en service (BA)
TRANSIC111LP
Capteur d’oxygène à laser
EN FR 01/01/2025Langue:
French
Version:
01/01/2025
Taille du fichier:
6.9 MB
Nom du fichier:
8030489_AE00_OI_TRANSIC111LP_fr_V3-1_2020-06_EHS.pdf
-
-
-
Manuel de mise en service (BA)
TRANSIC121LP
Laser Oxygen Transmitter
EN FR 01/01/2025Langue:
Anglais
Version:
01/01/2025
Taille du fichier:
6.7 MB
Nom du fichier:
8029876_17ZP_OI_TRANSIC121LP_en_V3-1_2020-09_EHS.pdf
-
-
-
Manuel de mise en service (BA)
TRANSIC151LP
Laser Oxygen Transmitter
EN FR 01/01/2025Langue:
Anglais
Version:
01/01/2025
Taille du fichier:
6.7 MB
Nom du fichier:
8029872_ZUQ7_OI_TRANSIC151LP_en_V1-3_2020-06_EHS.pdf
-
-
-
Manuel de mise en service (BA)
TRANSIC151LP USB Interface
Additional technical information on the USB-Interface and
entering commands via the serial interfaceEN FR 01/01/2025Langue:
Anglais
Version:
01/01/2025
Taille du fichier:
2.1 MB
Nom du fichier:
8030986_AE00_SD_TRANSIC151LP_USB_Interface_en_V1-0_2014-01_EHS.pdf
-
-
-
Conseils de sécurité Ex (XA)
Safety Information
for non-Ex analyzer devices
(multi-lingual, also in DE, BG, CS, DA, EL, ES, ET, FI, FR, HR, HU, IT,
LT, LV, NL, NO, PL, PT, RO, RU, SK, SL, SV)Langue:
Anglais
Version:
01/01/2025
Taille du fichier:
2.4 MB
Nom du fichier:
8030257_XA_Safety_Information_non-Ex_ml_V1-0_2016-06_WEB.pdf
-
-
-
Documentation spéciale (SD)
TRANSIC151LP - USB Interface
Addendum to Operating Instructions with technical information on the
TRANSIC151LP USB-Interface and entering commands via
the serial interface.EN FR 01/01/2025Langue:
Anglais
Version:
01/01/2025
Taille du fichier:
2.1 MB
Nom du fichier:
8030986_AE00_SD_TRANSIC151LP_USB_Interface_en_V1-0_2014-01_EHS.pdf
-
-
-
Documentation spéciale (SD)
TRANSIC100LP Cleaning Set
Cleaning bottle for cleaning optical components
EN FR 01/01/2025Langue:
Anglais
Version:
01/01/2025
Taille du fichier:
662.6 KB
Nom du fichier:
8030983_AE00_SD_TRANSIC100LP_Cleaning_Set_en_V1-0_2014-05_EHS.pdf
-
-
-
Solution pour l'industrie (SO)
Solutions for oil and gas industry
Endress+Hauser offers the best solutions through a huge range of products and systems to measure and perform even under the most
rigorous operating conditions.Langue:
Anglais
Version:
01/01/2025
Taille du fichier:
3.3 MB
Nom du fichier:
8030418_SO_Ol_and_Gas_en_V1-0_2025.01_EHS.pdf
-
-
-
Solution pour l'industrie (SO)
Solutions for chemicals, petrochemicals and refineries
Endress+Hauser offers a broad product portfolio of continuous gas analyzers using state-of-the-art technologies.
Langue:
Anglais
Version:
01/01/2025
Taille du fichier:
3.1 MB
Nom du fichier:
8030415_CPR_en_V1-0_2025.01_EHS.pdf
-
-
-
Brochure Compétence (CP)
Soluzioni per il monitoraggio delle emissioni
Soluzioni per il monitoraggio delle
emissioni
Ampio portfolio e vasta esperienzaLangue:
Italien
Version:
27/05/2025
Taille du fichier:
4.5 MB
Nom du fichier:
CP01596C16IT01.25-00.pdf
-