Raman spectroscopy - advanced optical analysis technology
Boost plant safety, ensure product quality, and optimize operations. Raman spectroscopy measures the composition and molecular structure of your samples from lab-to-process in real time.
Raman Rxn-10 probe
Body: 316L stainless steel
Window: Proprietary material, optimized for bioprocesses
Process connection: PG13.5
Surface finish: Ra 15 with electropolish
Adhesive: USP Class VI and ISO 10993 compatible
Autoclave
Raman bIO-Optics are versatile immersion optics used in conjunction with the Rxn-10 probehead and compatible with standard bioreactor ports. The fixed focus design provides long-term measurement stability along with superior signal performance, essential for transferable, high performance Raman-based bioprocess analysis. Available in industry standard lengths, Raman bIO-Optics are ideally suited for both glass and plastic benchtop bioreactor/fermenter applications requiring headplate entry.
Cell culture: glucose, lactate, glutamine, amino acids, cell density, titer
Fermentation: glycerol, methanol, ethanol, sorbitol, biomass
Downstream: aggregation, protein crystallization, formula stability, product CQA, protein concentration, buffer excipients
Immersion optics for multi-component bioprocess measurement
Compatible with standard bioreactor ports
Fixed-focus design
Available in 12 mm diameter with Pg 13.5 threaded connector
120, 220, 320, or 420 mm lengths
Autoclavable
High-end products
Technical excellence
Simplicity
Standard products
Technical excellence
Simplicity
Specialized products
Technical excellence
Simplicity
Variable
| FLEX selections | Technical excellence | Simplicity |
|---|---|---|
Fundamental selection Meet your basic measurement needs |
Technical excellence
|
Simplicity
|
Lean selection Handle your core processes easily |
Technical excellence
|
Simplicity
|
Extended selection Optimize your processes with innovative technologies |
Technical excellence
|
Simplicity
|
Xpert selection Master your most challenging applications |
Technical excellence
|
Simplicity
Variable |
System design and specifications for Rxn-10 probe optics:
Raman immersion optics (KIO1),
non-contact optics (KNCO1), bIO-Optics (KLBIO1),
bio multi optics (KRBMO), bio sleeves (KRBSL),
and Raman optic system for single use (KRSU1)
| EN | |||
|
31/05/2023
|
|
|
|
|
03/08/2022
|
|
|
|
Language: |
English |
|
Version: |
31/05/2023 |
|
File size: |
467.9 KB |
|
File name: |
TI01635CEN_0322.pdf |
System design and specifications for the Raman Rxn-10 probe
| EN | |||
|
08/09/2025
|
|
|
|
|
13/11/2024
|
|
|
|
|
31/05/2023
|
|
|
|
|
13/09/2022
|
|
|
|
|
08/09/2021
|
|
|
|
Language: |
English |
|
Version: |
08/09/2025 |
|
File size: |
949 KB |
|
File name: |
TI01629CEN_0525.pdf |
Commissioning, operation, and maintenance details
for Rxn-10 probe optics: Raman immersion optics (KIO1),
non-contact optics (KNCO1), bIO-Optics (KLBIO1),
bio multi optics (KRBMO), bio sleeves (KRBSL)
and Raman optic system for single use (KRSU1)
| EN | |||
|
31/05/2023
|
|
|
|
|
03/08/2022
|
|
|
|
|
14/09/2021
|
|
|
|
Language: |
English |
|
Version: |
31/05/2023 |
|
File size: |
1.8 MB |
|
File name: |
BA02171CEN_0322.pdf |
Commissioning, operation, and maintenance details
for the Raman Rxn-10 probe
| EN | |||
|
08/09/2025
|
|
|
|
|
02/12/2024
|
|
|
|
|
31/05/2023
|
|
|
|
|
13/09/2022
|
|
|
|
|
08/09/2021
|
|
|
|
Language: |
English |
|
Version: |
08/09/2025 |
|
File size: |
1.8 MB |
|
File name: |
BA02160CEN_0525.pdf |
Quick start guide for the Raman Rxn-10 probe
| EN | |||
|
02/12/2024
|
|
|
|
|
31/05/2023
|
|
|
|
|
13/09/2022
|
|
|
|
|
08/09/2021
|
|
|
|
Language: |
English |
|
Version: |
02/12/2024 |
|
File size: |
1.6 MB |
|
File name: |
KA01546CEN_0424.pdf |
Quickstart guide for Rxn-10 probe optics:
Raman immersion optics (KIO1),
non-contact optics (KNCO1), bIO-Optics (KLBIO1),
bio multi optics (KRBMO), bio sleeves (KRBSL),
and Raman optic system for single use (KRSU1)
| EN | |||
|
31/05/2023
|
|
|
|
|
03/08/2022
|
|
|
|
|
14/09/2021
|
|
|
|
Language: |
English |
|
Version: |
31/05/2023 |
|
File size: |
1 MB |
|
File name: |
KA01551CEN_0322.pdf |
A guide to our Raman spectroscopy application notes for the
Life Science industry (featuring the Raman Rxn2 analyzer,
Raman Rxn4 analyzer, Rxn-10 probe, Rxn-20 probe, Rxn-45 probe,
Rxn-46 probe, and probe accessory optics (bIO-Optic, Raman single
use optic system / SUB, immersion optic, non-contact optic).
|
Language: |
English |
|
Version: |
19/04/2022 |
|
File size: |
1.1 MB |
|
File name: |
PU01447CEN_0222.pdf |
A list of published technical articles related to Biopharma 4.0
topics with recommendations from Life Science industry experts
at Endress+Hauser.
|
Language: |
English |
|
Version: |
26/06/2025 |
|
File size: |
363.4 KB |
|
File name: |
PU01611CEN_0125.pdf |
Ein Leitfaden zu unseren Anwendungshinweisen zur
Raman-Spektroskopie für die Life-Science-Industrie
(Raman Rxn2-Analysator, Raman Rxn4-Analysator,
Rxn-10-Sonde, Rxn-20-Sonde, Rxn-45-Sonde,
Rxn-46-Sonde und Zubehör für Sondenoptiken
(blO-Optic, Raman- Single Use-Optiksystem
/ SUB, Immersionsoptik, berührungslose Optik)
|
Language: |
German |
|
Version: |
24/09/2025 |
|
File size: |
1.4 MB |
|
File name: |
PU01447CDE_0222_Raman-Anwendungsleitfaden_LSI_web.pdf |
ライフサイエンス産業向けラマン分光法アプリケーションノート(
ラマンRxn2アナライザー、ラマンRxn4アナライザー、Rxn-10プロー
ブ、Rxn-20プローブ、Rxn-45プローブ、Rxn-46プローブ、プローブ
オプティックアクセサリ(bIOオプティック、シングルユース向け
ラマンオプティックシステム/SUB、浸漬オプティック、非接触オプ
ティック)。
|
Language: |
Japanese |
|
Version: |
02/08/2024 |
|
File size: |
1.4 MB |
|
File name: |
PU01447CJA_0222_Raman_App_Guide_for_LifeScience.pdf |