Specs at a glance
-
Measured Variables
Concentration
Cell Pressure
Cell Temperature -
Hazardous area approvals
IECEx / ATEX / CNEx / KC / CCOE / CML Zone 1
Field of application
SS2100i gas analyzers accurately measure trace gas components (H2O, CO2, H2S, NH3, and C2H2) using tunable diode laser absorption spectroscopy (TDLAS) technology. The analyzers require little maintenance and do not need recalibration or periodic replacement parts. SS2100i gas analyzers are certified for ATEX/IECEx Zone 1.
Gas analysis: ppb level measurement of H2O & NH3, ppm level measurement of H2O, H2S, CO2, NH3, and C2H2, and % level measurement of H2S and CO2
Natural gas: production, storage, transportation, distribution
Refinery: hydrogen recycle, catalytic reforming, flaring, cracking
Gas processing: fractionation, sour/acid gas removal
LNG: liquefication, custody transfer
Petrochemical: cracking, acetylene converter, caustic wash tower
Biomethane: custody transfer measurements of CO2, H2S, H2O
Benefits
Accurate, real-time measurements not hampered by wet-up (absorption) or dry-down (desorption)
Virtually maintenance free and reliable in harsh environments
Dependable with greater repeatability than surface-based sensors with NIST-traceable calibration
Analog and serial outputs for remote monitoring
Low cost of ownership, no consumables
Available for the following measurements: H2O, CO2, H2S, NH3, C2H2
ATEX/IECEx Zone 1 certified
Xpert selection
-
Specialized products
- Designed for demanding applications
Technical excellence
Simplicity
Variable
-
Standard products
- Reliable, robust and low-maintenance
Technical excellence
Simplicity
-
Specialized products
- Designed for demanding applications
Technical excellence
Simplicity
Variable
FLEX selections | Technical excellence | Simplicity |
---|---|---|
Fundamental selection Meet your basic measurement needs |
Technical excellence
|
Simplicity
|
Lean selection Handle your core processes easily |
Technical excellence
|
Simplicity
|
Extended selection Optimize your processes with innovative technologies |
Technical excellence
|
Simplicity
|
Xpert selection Master your most challenging applications |
Technical excellence
|
Simplicity
Variable |
-
Measuring principle
TDLAS
-
Product Headline
An advanced gas analyzer for hydrogen sulfide (H2S) measurement. The SS2100i uses tunable diode laser absorption spectroscopy (TDLAS) to determine the concentration of the analyte without coming into physical contact with the stream.
-
Channels
1
-
Analyte and Measurement ranges
H2S (Hydrogen Sulfide):
0 to 10 ppmv
0 to 1000 ppmv
0 to 5000 ppmv
0 to 5% volume -
Measured Variables
Concentration
Cell Pressure
Cell Temperature -
Ambient Temperature range
-20 to 50°C (-4 to 122°F)
Optional (i-2 only): -10 to 60°C (14 to 140°F) -
Operating Pressure range
Inlet Pressure: 140 to 350 kPa (20 to 50 psig)
Sample Cell: 800 to 1200 mbara or 950 to 1700 mbara (optional) -
Analyzer Wetted materials
316L stainless steel
FKM O-Rings
Glass -
Power supply
120 or 240 VAC ± 10 %, 50 to 60 Hz; 300W
-
Communication
Analog Output: Two 4-20mA Isolated, 1200 ohms at 24 VDC max load (measurement value)
Analog Input: One 4-20mA Isolated, 1200 ohms at 24 VDC max load (process pressure)
Serial: RS232C and Ethernet
Protocol: Modbus Gould RTU or Daniel RTU or ASCII
Digital Outputs: 5, Concentration Alarm, General Fault, Validation Fail, Validation 1 Active, Validation 2 Active
Digital Inputs: 2, Flow Alarm, Validation Request -
Housing materials
Electronics: Copper-free Aluminum
Laser/Cell Enclosure: Copper-free Aluminum (i-2 only)
Sample System Enclosure: 304 or 316 stainless steel -
Hazardous area approvals
IECEx / ATEX / CNEx / KC / CCOE / CML Zone 1
-
Degree of protection
IP66
-
Product safety
CE
-
Metrological approvals
PAC China, Kazakhstan (i-1 only)
-
Measuring principle
TDLAS
-
Product Headline
An advanced gas analyzer for moisture (H2O) measurement. The SS2100i uses tunable diode laser absorption spectroscopy (TDLAS) to determine the concentration of the analyte without coming into physical contact with the stream.
-
Channels
1
-
Analyte and Measurement ranges
H2O (Moisture):
0 to 10 ppmv
0 to 100 ppmv
0 to 50 ppmv
0 to 5000 ppmv -
Measured Variables
Concentration
Moisture Dew Point
Cell Pressure
Cell Temperature -
Ambient Temperature range
-20 to 50°C (-4 to 122°F)
Optional (i-2 only): -10 to 60°C (14 to 140°F) -
Operating Pressure range
Inlet Pressure: 140 to 350 kPa (20 to 50 psig)
Sample Cell: 800 to 1200 mbara or 950 to 1700 mbara (optional) -
Analyzer Wetted materials
316L stainless steel
FKM O-Rings
Glass -
Power supply
120 or 240 VAC ± 10 %, 50 to 60 Hz; 300W
-
Communication
Analog Output: Two 4-20mA Isolated, 1200 ohms at 24 VDC max load (measurement value)
Analog Input: One 4-20mA Isolated, 1200 ohms at 24 VDC max load (process pressure)
Serial: RS232C and Ethernet
Protocol: Modbus Gould RTU or Daniel RTU or ASCII
Digital Outputs: 5, Concentration Alarm, General Fault, Validation Fail, Validation 1 Active, Validation 2 Active
Digital Inputs: 2, Flow Alarm, Validation Request -
Housing materials
Electronics: Copper-free Aluminum
Laser/Cell Enclosure: Copper-free Aluminum (i-2 only)
Sample System Enclosure: 304 or 316 stainless steel -
Hazardous area approvals
IECEx / ATEX / CNEx / KC / CCOE / CML Zone 1
-
Degree of protection
IP66
-
Product safety
CE
-
Metrological approvals
PAC China, Kazakhstan (i-1 only)
-
Measuring principle
TDLAS
-
Product Headline
An advanced gas analyzer for carbon dioxide (CO2) measurement. The SS2100i uses tunable diode laser absorption spectroscopy (TDLAS) to determine the concentration of the analyte without coming into physical contact with the stream.
-
Channels
1
-
Analyte and Measurement ranges
CO2 (Carbon Dioxide):
0 to 10 ppmv
0 to 1000 ppmv
0 to 5000 ppmv
0 to 5% volume
0 to 10% volume
0 to 20% volume -
Measured Variables
Concentration
Cell Pressure
Cell Temperature -
Ambient Temperature range
-20 to 50°C (-4 to 122°F)
Optional (i-2 only): -10 to 60°C (14 to 140°F) -
Operating Pressure range
Inlet Pressure: 140 to 350 kPa (20 to 50 psig)
Sample Cell: 800 to 1200 mbara or 950 to 1700 mbara (optional) -
Analyzer Wetted materials
316L stainless steel
FKM O-Rings
Glass -
Power supply
120 or 240 VAC ± 10 %, 50 to 60 Hz; 300W
-
Communication
Analog Output: Two 4-20mA Isolated, 1200 ohms at 24 VDC max load (measurement value)
Analog Input: One 4-20mA Isolated, 1200 ohms at 24 VDC max load (process pressure)
Serial: RS232C and Ethernet
Protocol: Modbus Gould RTU or Daniel RTU or ASCII
Digital Outputs: 5, Concentration Alarm, General Fault, Validation Fail, Validation 1 Active, Validation 2 Active
Digital Inputs: 2, Flow Alarm, Validation Request -
Housing materials
Electronics: Copper-free Aluminum
Laser/Cell Enclosure: Copper-free Aluminum (i-2 only)
Sample System Enclosure: 304 or 316 stainless steel -
Hazardous area approvals
IECEx / ATEX / CNEx / KC / CCOE / CML Zone 1
-
Degree of protection
IP66
-
Product safety
CE
-
Metrological approvals
PAC China, Kazakhstan (i-1 only)
-
Measuring principle
TDLAS
-
Product Headline
An advanced gas analyzer for ammonia (NH3) measurement. The SS2100i uses tunable diode laser absorption spectroscopy (TDLAS) to determine the concentration of the analyte without coming into physical contact with the stream.
-
Channels
1
-
Analyte and Measurement ranges
NH3 (Ammonia): 0 to 5 ppmv
-
Measured Variables
Concentration
Cell Pressure
Cell Temperature -
Ambient Temperature range
-20 to 50°C (-4 to 122°F)
Optional (i-2 only): -10 to 60°C (14 to 140°F) -
Operating Pressure range
Inlet Pressure: 140 to 350 kPa (20 to 50 psig)
Sample Cell: 800 to 1200 mbara or 950 to 1700 mbara (optional) -
Analyzer Wetted materials
316L stainless steel
FKM O-Rings
Glass -
Power supply
120 or 240 VAC ± 10 %, 50 to 60 Hz; 300W
-
Communication
Analog Output: Two 4-20mA Isolated, 1200 ohms at 24 VDC max load (measurement value)
Analog Input: One 4-20mA Isolated, 1200 ohms at 24 VDC max load (process pressure)
Serial: RS232C and Ethernet
Protocol: Modbus Gould RTU or Daniel RTU or ASCII
Digital Outputs: 5, Concentration Alarm, General Fault, Validation Fail, Validation 1 Active, Validation 2 Active
Digital Inputs: 2, Flow Alarm, Validation Request -
Housing materials
Electronics: Copper-free Aluminum
Laser/Cell Enclosure: Copper-free Aluminum (i-2 only)
Sample System Enclosure: 304 or 316 stainless steel -
Hazardous area approvals
IECEx / ATEX / CNEx / KC / CCOE / CML Zone 1
-
Degree of protection
IP66
-
Product safety
CE
-
Metrological approvals
PAC China, Kazakhstan (i-1 only)
-
Measuring principle
TDLAS
-
Product Headline
An advanced gas analyzer for acetylene (C2H2) measurement. The SS2100i uses tunable diode laser absorption spectroscopy (TDLAS) to determine the concentration of the analyte without coming into physical contact with the stream.
-
Channels
1
-
Analyte and Measurement ranges
C2H2 (Acetylene):
0 to 5 ppmv (minimum)
0 to 3000 ppmv (maximum) -
Measured Variables
Concentration
Cell Pressure
Cell Temperature -
Ambient Temperature range
-20 to 50°C (-4 to 122°F)
Optional (i-2 only): -10 to 60°C (14 to 140°F) -
Operating Pressure range
Inlet Pressure: 140 to 350 kPa (20 to 50 psig)
Sample Cell: 800 to 1200 mbara or 950 to 1700 mbara (optional) -
Analyzer Wetted materials
316L stainless steel
FKM O-Rings
Glass -
Power supply
120 or 240 VAC ± 10 %, 50 to 60 Hz; 300W
-
Communication
Analog Output: Two 4-20mA Isolated, 1200 ohms at 24 VDC max load (measurement value)
Analog Input: One 4-20mA Isolated, 1200 ohms at 24 VDC max load (process pressure)
Serial: RS232C and Ethernet
Protocol: Modbus Gould RTU or Daniel RTU or ASCII
Digital Outputs: 5, Concentration Alarm, General Fault, Validation Fail, Validation 1 Active, Validation 2 Active
Digital Inputs: 2, Flow Alarm, Validation Request -
Housing materials
Electronics: Copper-free Aluminum
Laser/Cell Enclosure: Copper-free Aluminum (i-2 only)
Sample System Enclosure: 304 or 316 stainless steel -
Hazardous area approvals
IECEx / ATEX / CNEx / KC / CCOE / CML Zone 1
-
Degree of protection
IP66
-
Product safety
CE
-
Metrological approvals
PAC China, Kazakhstan (i-1 only)
Choose from our suggested options
-
-- selected coding-- selected label99.999,00<%label%>
-
Looking for more options? Please use the individual configurator to continue
-
-- selected coding-- selected label99.999,00<%feature%>
-
<%label%>99.999,00
-
Looking for more options? Please use the individual configurator to continue
-
Process Connection
-
<%label%>99.999,00
-
<%label%>99.999,00
-
-
<%feature%><%coding%><%label%>
- CAD drawings CAD drawings
- CAD drawings
-
Prices per piece
-
<%range%><%price%>
-
- Optional add-ons
Individual configuration
Often bought together
Accessories