This product is no longer available.
Please check new generation in the section predecessor / successor or contact your local Endress+Hauser entity.
Level transmitter, continuous.
Measuring: ultrasonic, contactless.
Sensor enclosure: PVDF.
Max meas. range under ideal condition:
Liquid: 7m. Solid: 3.5m.
Blocking distance: 40cm.
Operating temperature -20...80oC
up to -40oC/-40oF with reduced range.
Max operating pressure 3bar abs.
Process connection: G2.
Integrated sound velocity compensation.
Self cleaning effect of sensor membrane.
:: Measuring range freely adjustable.
:: Simple calibration.
-
Successor
-
Standard products
- Reliable, robust and low-maintenance
Technical excellence
Simplicity
-
Specialized products
- Designed for demanding applications
Technical excellence
Simplicity
Variable
FLEX selections Technical excellence Simplicity - F
- L
- E
- X
Fundamental selection
Meet your basic measurement needs
Technical excellence Simplicity - F
- L
- E
- X
Lean selection
Handle your core processes easily
Technical excellence Simplicity - F
- L
- E
- X
Extended selection
Optimize your processes with innovative technologies
Technical excellence Simplicity - F
- L
- E
- X
Xpert selection
Master your most challenging applications
Technical excellence Simplicity Variable
-
-
Characteristic / Application
Open basins, Storage tanks
-
Supply / Communication
2-wire / 4 ... 20 mA
-
Accuracy
0,25 % of measuring range
-
Ambient temperature
-20 °C ... 60 °C
(-4 °F ... 140 °F) -
Process temperature
-40 °C ... 80 °C
(-40 °F ... 176 °F) -
Process pressure / max. overpressure limit
0.7 bar ... 3 bar abs
(10 psi ... 44 psi) -
Main wetted parts
PVDF
-
Process connection
G 2"
-
Blocking distance
0.4 m (1.3 ft)
-
Application
Application
-
Max. measurement distance
7 m (23 ft)
-
Communication
4 ... 20 mA
-
Application limits
Application limits
-
Characteristic / Application
Compact sensor
-
Supply / Communication
2-wire / 4 ... 20 mA
-
Accuracy
0,25 % of measuring range
-
Ambient temperature
-20 °C ... 60 °C
(-4 °F ... 140 °F) -
Process temperature
-40 °C ... 80 °C
(-40 °F ... 176 °F) -
Process pressure / max. overpressure limit
0.7 bar ... 3 bar abs
(10 psi ... 44 psi) -
Main wetted parts
PVDF
-
Process connection
NPT 2"
-
Blocking distance
0.4 m (1.3 ft)
-
Max. measurement distance
3.5 m (11 ft)
-
Communication
4 ... 20 mA
-
Application limits
Take notice of range diagram