Transmitter for the ultrasonic flow measurement of liquids.
Successor
Flowmeter for hazardous area installations with a wide range of analog and digital outputs. Ideal clamp-on device for applications with chemicals, solvents, liquid hydrocarbons, acids, alkalis.
Read more
Simple products
Easy to select, install and operate
Technical excellence
Simplicity
Standard products
Reliable, robust and low-maintenance
Technical excellence
Simplicity
High-end products
Highly functional and convenient
Technical excellence
Simplicity
Specialized products
Designed for demanding applications
Technical excellence
Simplicity
FLEX selections
Technical excellence
Simplicity
Fundamental selection
Meet your basic measurement needs
Technical excellence
Simplicity
Lean selection
Handle your core processes easily
Technical excellence
Simplicity
Extended selection
Optimize your processes with innovative technologies
Technical excellence
Simplicity
Xpert selection
Master your most challenging applications
Technical excellence
Simplicity
Most downloaded
Prosonic Flow DMU 93
Technical Information
English version - 11/1999
Ultrasonic Flow Measuring System Prosonic flow DMU 93
Flexible # Cost-effective # Innovative
Language:
English
Version:
01/11/1999
File size:
1.1 MB
File name:
TI042DEN.pdf
7 documents
Prosonic Flow DMU 93
Technical Information
Ultrasonic Flow Measuring System Prosonic flow DMU 93 Flexible # Cost-effective # Innovative
EN
German French
01/11/1999
Language:
English
Version:
01/11/1999
File size:
1.1 MB
File name:
TI042DEN.pdf
Prosonic Flow DMU 93 / DDU 10 / DDU 18
Operating Manual
Ultrasonic Flow Measuring System with "Clamp on" sensors.
EN
German French
01/12/1999
Language:
English
Version:
01/12/1999
File size:
1.6 MB
File name:
BA038DEN.pdf
Prosonic Flow DMU 93 / DDU 15
Operating Manual
Ultrasonic Flow Measuring System with insertion sensors.
EN
German French
01/12/1999
Language:
English
Version:
01/12/1999
File size:
2.1 MB
File name:
BA044DEN.pdf
Prosonic Flow DMU 93, ATEX II 3GEx documentation
Ex-Dokumentation zur Betriebsanleitung BA038D, BA044D. Ex documentation for the operating instruction BA038D, BA044D. Documentation Ex relative à la mise en service BA038D, BA044D.
EN
German French
01/01/2000
Language:
English
Version:
01/01/2000
File size:
690.1 KB
File name:
XA002DA3.pdf
Product family: Prosonic Flow DDU 10, Prosonic Flow DDU 18, PROSONIC FLOW
DDU 19
Product root: DDU10-, DDU15-, DDU18-, DDU19-, DMU93- Region: USA Approval agency: FM Category: I,II,III/1/A,B,C,D,E,F,G/ Protection: DIP
Language:
English
Version:
20/04/2006
File size:
437.2 KB
File name:
FM3000398_FES0008-F0B.pdf
Device Type Manager (DTM) - Prosonic Flow DMU 93 - HART
Endress+Hauser, DeviceCare, 1.07.06 Endress+Hauser, Field Xpert - SMT70, 1.07.00 Endress+Hauser, FieldCare, 2.17.00
Language:
Language neutral
Version:
12/05/2023
File size:
228.1 MB
File name:
EH_Prosonic_Flow_DMU93_V1_01_00.zip
Device Type Manager (DTM) - Prosonic Flow DMU 93 - HART
Endress+Hauser, DeviceCare, 1.07.06 Endress+Hauser, Field Xpert - SMT70, 1.07.00 Endress+Hauser, FieldCare, 2.17.00
Language:
Language neutral
Version:
12/05/2023
File size:
228.1 MB
File name:
EH_Prosonic_Flow_DMU93_V1_00_00.zip
Search spare parts by number in drawing
60 spare parts & accessories
60 spare parts & accessories
60 spare parts & accessories
Kit power supply DMU93 85-260VAC
Drawing number
Order code
E
50093587
Kit pow supp. DMU93 20-55VAC/16-62VDC
Drawing number
Order code
E
50093588
Kit filter board 85-260VAC Ex
Drawing number
Order code
F
50093532
Kit filter board 20-55VAC/16-62VDC Ex
Drawing number
Order code
F
50093533
Kit filter board 85-260VAC
Drawing number
Order code
F
50093542
Kit filter board 20-55VAC/16-62VDC
Drawing number
Order code
F
50093543
Kit 10 fuses 250 VAC 1A00 slow-blow
Drawing number
Order code
4
50093519
Kit 10 fuses 250 VAC 2A50 slow-blow
Drawing number
Order code
4
50093524
Kit meas. amplifier DMU93
Drawing number
Order code
B
50093619
Kit base support 3X/6X/DMU93
Drawing number
Order code
1
50093663
Kit commodule DMU93 HART+freq. Ex i
Drawing number
Order code
C
50093584
Kit commodule DMU93 HART+freq. Ex
Drawing number
Order code
C
50093585
Kit commodule DMU93 2 current outputs
Drawing number
Order code
C
50093586
Kit software DMU93 commodule current
Drawing number
Order code
3
50096213
Kit display module Prosonic F 93
Drawing number
Order code
D
50093620
Kit conn. board 3X/60/63/DMU93electr.
Drawing number
Order code
G
50093526
Kit DAT memory 3X/6X/DMU93
Drawing number
Order code
2
50093528
Kit cover 3X/6X/DMU93 with window
Drawing number
Order code
6
50093645
Kit cover 3X/6X/DMU93 + window Ex d
Drawing number
Order code
6
50093650
Kit cover terminal compartment
Drawing number
Order code
8
50093641
Kit cover terminal compartment Ex d
Drawing number
Order code
8
50093647
Kit 10 cable glands PG 13.5
Drawing number
Order code
5
50093667
Kit 2 cable glands M26/PG 13.5
Drawing number
Order code
5
50093675
Kit 2 cable glands M26/M20x1.5
Drawing number
Order code
5
50093676
Kit 2 cable glands M26/NTP 1/2"
Drawing number
Order code
5
50093677
Kit 2 cable glands M26/G 1/2"
Drawing number
Order code
5
50093678
Kit gaskets housing 3X/6X/DMU93 comp
Drawing number
Order code
9
50093633
Kit housing 3X/6X/DMU93 85-260VAC
Drawing number
Order code
H
50093643
Kit hous. 3X/6X/DMU93 20-55AC/16-62DC
Drawing number
Order code
H
50093644
Kit parts housing 3X/6X/DMU93
Drawing number
Order code
10
50093664
Label wiring PROMASS 2 current
Connec. label PROMAG/PROMASS Ex i/IS
Replacement name plate set
Electronics insert module DMU 93