Raman spectroscopy - advanced optical analysis technology
Boost plant safety, ensure product quality, and optimize operations. Raman spectroscopy measures the composition and molecular structure of your samples from lab-to-process in real time.
316L option
Metal: 316L stainless steel
Window: High-purity sapphire
C276 option
Metal: C276 alloy
Window: High-purity sapphire
Titanium option
Metal: Grade 2 titanium
Window: High-purity sapphire
Hybrid metal combination option
Metal: 316L stainless steel, C276 alloy
Window: High-purity sapphire
ATEX, CSA, IECEx
The Raman Rxn-41 probe is a rugged, process insertion probe with no sample handling system. Its single cable design streamlines installation, eliminates risk scenarios, and minimizes installation cost for long fiber runs in the process environment. The Rxn-41 probe is ideally suited for use in chemical plants and refineries to measure batch or continuous flow production. For direct measurements in cryogenic fluids, an optimized cryogenic version of the Raman Rxn-41 probe is available.
Chemical: reaction monitoring, blending, feed and final product monitoring
Polymer: polymerization reaction monitoring, polymer blending
Pharmaceutical: API reaction monitoring, crystallization, polymorph, drug substance production unit operation
Oil & Gas: fuel blending, fuel characterization
Constructed to individual site requirements
Sealed probe design
Integrated “laser on” indicator
One in/one out fiber optics
Direct insertion compatibility
Meets Category 1 pressure equipment safety standards
Suitable for hazardous area/classified environments
High-end products
Technical excellence
Simplicity
Standard products
Technical excellence
Simplicity
Specialized products
Technical excellence
Simplicity
Variable
FLEX selections | Technical excellence | Simplicity |
---|---|---|
Fundamental selection Meet your basic measurement needs |
Technical excellence
|
Simplicity
|
Lean selection Handle your core processes easily |
Technical excellence
|
Simplicity
|
Extended selection Optimize your processes with innovative technologies |
Technical excellence
|
Simplicity
|
Xpert selection Master your most challenging applications |
Technical excellence
|
Simplicity
Variable |
English version - 12/2023 |
System design and specifications for the Raman Rxn-41 probe
Language: |
English |
Version: |
08/12/2023 |
File size: |
1.5 MB |
File name: |
TI01673CEN_0423.pdf |
System design and specifications for the Raman Rxn-41 probe
Language: |
English |
Version: |
08/12/2023 |
File size: |
1.5 MB |
File name: |
TI01673CEN_0423.pdf |
Commissioning, operation, and maintenance details
for the Raman Rxn-41 probe
EN | |||
10/08/2023
|
|
|
Language: |
English |
Version: |
10/08/2023 |
File size: |
2.3 MB |
File name: |
BA02190CEN_0323.pdf |
Quick start guide for the Raman Rxn-41 probe
Language: |
English |
Version: |
10/08/2023 |
File size: |
1.9 MB |
File name: |
KA01560CEN_0323.pdf |
Instructions for use of the LNG analyzer performance verification kit
Language: |
English |
Version: |
30/03/2023 |
File size: |
442.7 KB |
File name: |
EA01470CEN_0123.pdf |
Raman Rxn-41 分光プローブの危険場所で使用するための認定および設置説明
EN | |||
08/08/2023
|
|
|
|
01/07/2022
|
|
|
Language: |
English |
Version: |
08/08/2023 |
File size: |
2.6 MB |
File name: |
XA02784CJA_0323.pdf |
An overview brochure about our Raman Rxn5 analyzer (including
the Raman Rxn-30 probe, the Rxn-40 probe, and the Rxn-41 probe),
a Raman spectroscopy analyzer system for gas phase measurements
powered by Kaiser Raman technology.
Language: |
English |
Version: |
28/10/2021 |
File size: |
499.9 KB |
File name: |
PU01444CEN_0121.pdf |
A guide to our Raman spectroscopy analyzer and probe portfolio,
powered by Kaiser Raman technology, for composition analysis of
gas streams and LNG (includes the Raman Rxn4 analyzer, the
Raman Rxn5 analyzer, the Raman Rxn-30 probe, and
Raman Rxn-41 probe) in the chemical industry and oil & gas industry.
Language: |
English |
Version: |
08/12/2021 |
File size: |
2.5 MB |
File name: |
PU01445CEN_0121.pdf |
An overview brochure about the Raman Rxn-41 probe, a
Raman spectroscopy probe for cryogenic liquid measurement
powered by Kaiser Raman technology in the Oil & Gas /
LNG industry.
Language: |
English |
Version: |
20/01/2022 |
File size: |
496 KB |
File name: |
PU01450CEN_0122.pdf |
A list of industry gas quality standards that our Raman Rxn5
analyzer meets for syngas / LNG and our Raman Rxn4
analyzer meets for LNG.
Language: |
English |
Version: |
20/04/2022 |
File size: |
432.5 KB |
File name: |
PU01463CEN_0122.pdf |
化学産業および石油・ガス産業におけるガスストリームおよび LNG の組成分析用(Raman Rxn4 アナライザー、
Raman Rxn5 アナライザー、Raman Rxn-30 プローブ、Raman Rxn-41 プローブを含む)、
Kaiser Raman テクノロジーによるラマン分光アナライザーおよびプローブ製品ラインアップのご案内です。
Language: |
Japanese |
Version: |
13/05/2024 |
File size: |
4.2 MB |
File name: |
PU01445CJA_0121_RamanAnalyzer_AppGuide_OilGas_ChemInd.pdf |
オイル&ガス/LNG産業におけるKaiser Raman テクノロジーによるによる極低温液体測定用ラマン分光プローブ、
Raman Rxn-41プローブの概要パンフレット。
Language: |
Japanese |
Version: |
13/05/2024 |
File size: |
919.6 KB |
File name: |
PU01450CJA_0122_Raman_Rxn41.pdf |
An overview brochure about our Raman spectroscopy analyzer systems,
powered by Kaiser Raman technology, for the chemical industry
(includes the Raman Rxn2 analyzer, Raman Rxn4 analyzer,
Raman Rxn5 analyzer, and the Raman Rxn-10 probe, Raman Rxn-20 probe,
Raman Rxn-30 probe, Raman Rxn-40 probe, and Raman Rxn-41 probe).
Language: |
English |
Version: |
18/10/2021 |
File size: |
10.6 MB |
File name: |
IN01223CEN_0121.pdf |
An overview brochure about our Raman spectroscopy probe
portfolio including the Rxn-10 probe, Rxn-20 probe, Rxn-30 probe,
Rxn-40 probe, Rxn-41 probe, Rxn-45 probe, Rxn-46 probe, and
probe accessory optics (bIO-Optic, Raman single use optic system /
SUB, immersion optic , non-contact optic), powered by Kaiser Raman
technology.
Language: |
English |
Version: |
26/10/2021 |
File size: |
4.9 MB |
File name: |
IN01225CEN_0121.pdf |
An overview brochure about our Raman spectroscopy
analyzer systems,powered by Kaiser Raman technology,
for the LNG industry / Oil & Gas industry (includes the
Raman Rxn4 analyzer, the Raman Rxn5 analyzer, and the
Raman Rxn-41 probe).
Language: |
English |
Version: |
19/04/2022 |
File size: |
13.5 MB |
File name: |
IN01222CEN_0222.pdf |
-
Language: |
French |
Version: |
16/03/2023 |
File size: |
776 KB |
File name: |
IN01225CFR.pdf |
プロセスラインにおける信頼性の高い組成測定
Language: |
Japanese |
Version: |
01/03/2023 |
File size: |
16.5 MB |
File name: |
IN01223CJA_0121.pdf |
A portfolio overview brochure about our TDLAS and Raman
spectroscopy analyzer systems for the LNG / Oil & Gas industry
(includes the SS2100, SS2100i, SS2100a, J22, JT33, Raman Rxn4
and Raman Rxn5 analyzers, and the Raman Rxn-41 probe).
Language: |
English |
Version: |
27/11/2023 |
File size: |
12.2 MB |
File name: |
IN01281CEN_0223.pdf |
This whitepaper details the GERG report findings on the use
of a Raman Rxn4 analyzer and Raman Rxn-41 cryogenic
probe for th
e reliable chemical composition measurement in
LNG custody transfer applications.
Language: |
English |
Version: |
08/08/2023 |
File size: |
2.2 MB |
File name: |
WP01180CEN_0223.pdf |
This whitepaper examines the role of Raman spectroscopy
(including a Raman Rxn4 analyzer, Raman Rxn5 analyzer,
and Rxn-41 probe) and TDLAS (J22 and SS2100 gas analyzers)
to measure LNG quality.
Language: |
English |
Version: |
13/09/2022 |
File size: |
1.8 MB |
File name: |
WP01185CEN_0122.pdf |
Thisapplication note examines the use of a Raman Rxn5 analyzer
to measure the composition of mixed refrigerant in the LNG
liquefactionprocess.
Language: |
English |
Version: |
03/12/2021 |
File size: |
371 KB |
File name: |
AI01346CEN_0121.pdf |
This application note examines the use of a RamanRxn5 analyzer
to measure the composition of LNG in the rundown lines.
Language: |
English |
Version: |
03/12/2021 |
File size: |
461.8 KB |
File name: |
AI01348CEN_0121.pdf |
This application note examines the use of a Raman Rxn4 analyzer
to accurately measure the composition of LNG at truck loading.
Language: |
English |
Version: |
03/12/2021 |
File size: |
587.4 KB |
File name: |
AI01349CEN_0121.pdf |
This application note examines the use of a Raman Rxn4 analyzer to
accurately measure LNG composition during baseload custody transfer.
Language: |
English |
Version: |
03/12/2021 |
File size: |
588.9 KB |
File name: |
AI01345CEN_0121.pdf |
This application note examines the use of a Raman Rxn4 analyzer to
measure LNG composition during natural gas quality adjustment
processes.
Language: |
English |
Version: |
03/12/2021 |
File size: |
429.7 KB |
File name: |
AI01347CEN_0121.pdf |
This application note examines the use of a Raman Rxn4 analyzer
to accurately measure the full composition of bunkered LNG.
Language: |
English |
Version: |
03/12/2021 |
File size: |
639.7 KB |
File name: |
AI01350CEN_0121.pdf |
Product root: KR10-, KR20-, KR30-, KR40-, KR41-, KR45-, KR46-
Declaration number: HE_01661_01.22
Manufacturer specification: Food hygiene
Additional information: HALAL Declaration
Language: |
English |
Version: |
27/10/2019 |
File size: |
100.8 KB |
File name: |
4004815 Supplier Declaration HALAL.pdf |
Product root: KR20-, KR30-, KR40-, KR41-
Declaration number: EU_00994_02.23
Additional information: EU Declaration of Conformity, Probes
Language: |
English |
Version: |
19/06/2023 |
File size: |
112.5 KB |
File name: |
4002257_02.23 EU Declaration of Conformity Probes ATEX.pdf |
Product root: KR20-, KR30-, KR40-, KR41-
Region: USA
Approval agency: CSA
Protection: Ex i
Language: |
English |
Version: |
31/07/2023 |
File size: |
175.5 KB |
File name: |
Probes NA CoFC_80176239_EN.pdf |
Product root: KR20-, KR30-, KR40-, KR41-
Region: Great Britain
Approval agency: CSA
Protection: Ex i Zone 0/1
Language: |
English |
Version: |
28/07/2023 |
File size: |
593.2 KB |
File name: |
Probes UKCA CSAE 22UKEX1305X Iss 1.pdf |
Product root: KR20-, KR30-, KR40-, KR41-
Region: Japan
Approval agency: CSA
Protection: Ex i Zone 0
Language: |
English |
Version: |
24/10/2023 |
File size: |
375.8 KB |
File name: |