Training
EngyCal RS33
Steam calculator
Steam calculator for recording steam mass and energy flow for saturated or superheated steam
The steam calculator EngyCal RS33 is used to record steam mass and energy flow of saturated and superheated steam. The calculation is based on the measured process variables volume flow, temperature and/or pressure.
The EngyCal RS33 uses the standard IAPWS IF97 to calculate the mass and energy flow of steam. The density and enthalpy of the steam are calculated from the input variables pressure and temperature.
-
Standard products
- Reliable, robust and low-maintenance
Technical excellence
Simplicity
-
Specialized products
- Designed for demanding applications
Technical excellence
Simplicity
Variable
FLEX selections | Technical excellence | Simplicity |
---|---|---|
Fundamental selection Meet your basic measurement needs |
Technical excellence
|
Simplicity
|
Lean selection Handle your core processes easily |
Technical excellence
|
Simplicity
|
Extended selection Optimize your processes with innovative technologies |
Technical excellence
|
Simplicity
|
Xpert selection Master your most challenging applications |
Technical excellence
|
Simplicity
Variable |
-
Specs at a glance
-
Input
1x Puls/Analog for flow
2x RTD/Analog for temperature and pressure
Loop power supply 24V DC (+/-16%) -
Output
1x 4...20mA
2x digital (Open Collector) -
Display
160 x 80 Dot-Matrix LCD with white backlit
colour change in case of alarm event
active display area 70 x 34 mm -
Calculations
IAPWS-IF97
-
Quick selection
Individual configuration
-
Benefits
Compensation of differential pressure flow measurement
Calculation according to international water steam tables
Electronic matching of the temperature sensor (sensor-transmitter matching) with the arithmetic unit enables highly accurate temperature...
-
Field of application
Recording and billing energy quantities in steam applications (steam heat quantity, steam heat differential). Typical applications include:
Food industry
Chemical industry
Pharmaceutical industry
Power plants
Building systems and plant engineering
Documents / Manuals / Software
-
Technical Information EngyCal RS33
RS33 Steam calculator for recording and
billing steam mass and energy flow for applications with saturated or
superheated steamTechnical Information (TI) -
EngyCal RH33 and RS33 and Batch Controller RA33
Operating Instructions
Additional operating instructions Modbus for BTU meter RH33, Steam
calculator RS33 and Batch Controller RA33Operating Instruction (BA) -
EngyCal RS33
Operating Instructions
Operating Instructions EngyCal RH33 steam calculator
Operating Instruction (BA) -
FDM Field Data Manager Software MS20, MS21
Data management and visualization
Operating Instruction (BA) -
EngyCal RS33
Brief Operating Instructions
Brief operating instructions steam calculator EngyCal RS33
Short Instruction (KA)01/15English -
Manufacturer information for RS33
Software update to new Firmware version for EngyCal RS33
Manufacturer Information (MI) -
Liczniki EngyCal- NiS_10_2010
Przejrzyste monitorowanie zużycia nośników energii w postaci cieczy i
pary.Publications (PU)04/12Polish -
Sistem Bileşenleri ve Kayıt Cihazları
Sisteminiz için tamamlayıcı çözümler
Fields of Activities (FA)10/14Turkish -
Системные компоненты и Регистраторы
Обзор продукции
Fields of Activities (FA)06/13Russian -
Componentes de sistema y registradores
Soluciones para el lazo de control
Indicadores, dispositivos de interfaz, protección contra sobretensiones,
gestores de aplicaciones y energía, registradores sin papel y paquetes
de software asociado para la automatización de procesos.Fields of Activities (FA)05/20Spanish -
System Components
e Data Managers
Componenti di sistema e data manager
Soluzioni per il completamento del punto di misuraFields of Activities (FA)04/18Italian -
System Components and Data Managers
Solutions for the loop
Indicators, interface devices, surge arresters, energy and application
managers, data managers, paperless recorders and associated
software packages for process automationFields of Activities (FA)04/18Polish -
System Products and Data Managers
Solutions for the loop
Indicators, interface devices, surge arresters, energy and application
managers, data managers, paperless recorders and associated
software packages for process automationFields of Activities (FA)02/20English -
Systemprodukte und Datenmanager
Lösungen zur Komplettierung der Messstelle
Anzeiger, Interfacegeräte, Überspannungsschutz, Energie- und
Applikationsmanager, Datenmanager, Bildschirmschreiber und
Softwarepakete für die ProzessautomatisierungFields of Activities (FA)02/20German -
Produits système et data managers
Solutions associées
Fields of Activities (FA)01/19fr -
Brochure Condensed Launch EngyCal® RH33 and RS33
Product Launch
EngyCal® RH33
BTU Meter
EngyCal® RS33
Steam Calculator
Brochure Condensed LaunchCompetence Brochure (CP)07/10English -
Brochure Condensed Launch EngyCal® RH33 and RS33
Product Launch
EngyCal® RH33
BTU Meter
EngyCal® RS33
Steam Calculator
Brochure Condensed LaunchCompetence Brochure (CP)07/10German -
Monitoring pare se isplatio za manje od dvije godine
Ključ u ruke rješenje monitoringa pare omogućuje sistematično smanjenje
troškova energije.Case Studies (CS)03/13Language neutral -
Steam monitoring pays off in less than two years
Turnkey steam monitoring solution enables the systematic reduction of
energy costsCase Studies (CS)02/13English -
Le contrôle de la vapeur amorti en moins de deux ans
ArcelorMittal Zenica réduit significativement ses coûts énergétiques
Case Studies (CS)02/13fr -
IN00014R EngyCal® The RH33 BTU meter and RS33 steam calculator
for US market
Find your energy wasters
Monitoring and billing of liquid or steam heat and cooling quantities
Custody transfer approval per MID and EN 1434
Bi-directional measurement in heating and cooling systems
Remote display via Ethernet and fieldbus
interfaceElectronic pairing of temperature sensors by means of
individual sensor characteristic curves stored in the deviceInnovations (IN)11/11English -
EngyCal RS33 Dampfrechner
Energiemanager zur Berechnung von Masse und Energie von Dampf
Tender Text11/16German -
DTM Single, EngyCal_RS33_CDI_FW_1_04_zz_Dev_Rev_n_a, 18.11.2020 (Components, EngyCal, 0x66FD)
Common Device Interface,
DeviceCare Version: 1.07.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.7.0.5Language neutral -
DTM Single, EngyCal_RS33_CDI_FW_1_01_zz_Dev_Rev_n_a, 18.11.2020 (Components, EngyCal, 0x66FD)
Common Device Interface,
DeviceCare Version: 1.07.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.1.6.3352Language neutral -
DTM Single, EngyCal_RS33_CDI_FW_1_03_zz_Dev_Rev_n_a, 18.11.2020 (Components, EngyCal, 0x66FD)
Common Device Interface,
DeviceCare Version: 1.07.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.1.6.3352Language neutral -
DTM Single, EngyCal_RS33_CDI_FW_1_02_zz_Dev_Rev_n_a, 18.11.2020 (Components, EngyCal, 0x66FD)
Common Device Interface,
DeviceCare Version: 1.07.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.1.6.3352Language neutral -
ComDTM Single, CDI_CommDTM, 02.12.2019
Common Device Interface,
DeviceCare Version: 1.05.00
FieldCare Version: 2.13.00Communication DTM2.09.07Language neutral -
contactors / transmitters
Product Code: RS33-
Declaration Number: HE_00449_02.17
Manufacturer Specification: RoHSManufacturer DeclarationChinese -
contactors / transmitters
Product Code: RA33-, RH33-, RS33-
Declaration Number: EC_00380_01.16EU DeclarationGerman , English , fr -
Soliswitch, process displays, Preline, power supply and barrier, power supply, over voltage protector, Mini-Log, Memo-Graph, Ecograph, controller, contactors / transmitters, Configuration Kit
Product Code: RIA452-, RIA452L-, RIA46-, RID14-, RID16-, RMA42-, RMC621-, RMC621L-, RMS621-, RMS621L-, RN221N-, RN221NL-, RNB130-, RNS221-, RNS221L-, RS33-, RSG35-, RSG40-, RSG45-, RTA421-, RTA421L-, TXU10-, RIA45-, FML621-, FTE20-, FTE30-, FTE31-, HAW562-, HAW569-, OFTE20-, ORIA15-, ORIA45-, ORIA46-, ORMA42-, ORSG35-, ORSG45-, OSG40-, OSG45-, RA33-, RB223-, RDL10-, RH33-, RIA14-, RIA15-, RIA16-
Declaration Number: EC_00569_01.17EU DeclarationGerman , English , fr -
contactors / transmitters
Product Code: RH33-, RS33-
Region/Country: Russia (TR CU)
Approval Agency: EAC
Approval Number: TC BY_112 11.01. TP004 003 168MiscellaneousRussian -
contactors / transmitters
Product Code: RH33-, RS33-
Region/Country: Russia (TR CU)
Approval Agency: EAC
Approval Number: TC BY_112 11.01. TP020 003 126MiscellaneousRussian -
contactors / transmitters
Product Code: RA33-, RH33-, RS33-
Region/Country: Canada
Approval Agency: CSA
Category: GPOrdinary Location Product SafetyEnglish
Accessories / Spare parts
-
-
Order code RK01-AJ
RH/RS/RA33 pipe mounting set
-
Order code RK01-AV
RH/RS/RA33 mounting set wall
-
-
-
Nr 5 Order code XPR0001-SK
Cable entry set panel mounting: 4xM20, 2xM12, 1xM25
-
-
-
Order code 51009210
-
-
-
Nr 9 Order code 71084277
Terminal plug 2pole space5.0
-
-
-
Order code RK01-AK
RH/RS/RA33 DIN rail mounting set
-
-
-
Nr 4 Order code XPR0001-SP
Small parts set: hinge pin, pressure compensation element, USB-cover, seal panel
-
-
-
Nr 3 Order code XPR0001-CP
Cover electronic internal for RH33 + RS33 incl. screws (for Mainboard + CPU card)
-
-
-
Nr 2 Order code XPR0001-UT
Housing lower for Rx33 incl. counter plate (please order name plate separately with DIENST-T)
-
-
-
Order code RK01-AL
RH/RS/RA33 panel mounting set
-
-
-
Nr 1 Order code XPR0001-FS
Housing front RS33 incl. front foil
-
-
-
Nr 8 Order code XPR0001-KA
Communication board USB
-
Nr 8 Order code XPR0001-KB
Communication board USB + Ethernet + ModBus TCP
-
Nr 8 Order code XPR0001-KC
Communication board USB + ModBus RTU (RS485)
-
Nr 8 Order code XPR0001-KD
Communication board USB + MBus (for RH33 and RS33)
-
-
-
Nr 7 Order code XPR0002-
-
-
-
Nr 6 Order code XPR0003-
Main board Rx33, XPR0003
-
-
-
Order code XPR0004-
Software Rx33, XPR0004
-
Order code MS20-
Field Data Manager Software MS20
Visualization software and database for visualization of historical data like measured values, calibration or configuration. Manipulation protected SQL database, graphical visualization, tables for measured values, alarms or events, online help, user administration, Automatic read out of device data. Automatic data export in various formats or in secured format for backup or reduction of database. Note: The version FDM essential only supports RSG30, RSG35, RSG40 as well as RSG45 and has a restricted functionality.
-