The Bunker Metering Computer SBC600 collects, visualizes and stores bunkering data from all involved devices. Out of that data the Bunker Metering Computer will create batch tickets and metering profiles. The measuring system immediately reports irregularities during bunkering, making it possible to intervene quickly.
The Bunker Metering Computer SBC600 is an integral part of the complete Bunker Metering Solution delivered by Endress+Hauser.
The intuitive operator interface ensures optimal control over the entire fueling process and safe operation due to immediate visualization of error messages. The Bunker Metering Computer SBC600 guarantees maximum operating convenience. This means less stress for the operator throughout the entire bunkering process. Thanks to the custody transfer approved the system is accepted worldwide and is fully tamper-proofed due to sealed components.
Benefits
Continuous bi-directional mass flow measurement using Coriolis flowmeters from Endress+Hauser.
Patent dual phase flow measurement for maximum on accuracy even under severe conditions like tank stripping and maximum on application safety and measurement availability.
The metering profile immediate intervention during excessive tank stripping or air injection is possible. Therefore no more time consuming and costly bunker disputes because of non-transparent bunkering operation.
The custody transfer approved system delivers worldwide acceptance of measuring results. Transparency and traceability of setting changes is ensured by the audit trail.
The intuitive and integrated 12” operating panel, touch screen (HMI) guarantees safe operation due to immediate visualization of error messages.
Déchargement homologué à l'étalonnage
de navires avec une précision suisse
Case Study (CS)
French version - 02/2019
New version available in English
Environ 250 bateaux-citernes accostent chaque année aux deux stations d'accostage de VARO Energy Tankstorage AG dans le port rhénan de Birsfeld. Grâce au système de mesure de débit d'Endress+Hauser, le processus de transbordement a pu être accéléré et le volume de chargement déterminé avec précision et rapidité pendant le déchargement.
Dynamic flow measurement in the Rhine port of Birsfelden -
Swiss-precision ship unloading for custody transfer applications
Case Study (CS)
English version - 02/2019
New version available in English
Approximately 250 tankers dock here each year at the two mooring stations located at VARO Energy Tankstorage AG in the Rhine port of Birsfelden. Endress+Hauser's flowmeter system has made it possible to speed up the unloading process and to record the load volume accurately and in real-time during unloading.
Dynamische Durchflussmessung - Eichfähige
Schiffsentladung mit Schweizer Präzision
Case Study (CS)
German version - 02/2019
New version available in English
Rund 250 Tankschiffe docken jährlich an den zwei Anlegestationen bei der VARO Energy Tankstorage AG im Birsfelder Rheinhafen an. Mit dem Durchflussmesssystem von Endress+Hauser konnte der Löschvorgang beschleunigt - und das Ladevolumen exakt und zeitnah, während der Entladung, bestimmt werden.