Specs at a glance
-
Process temperature
Any
-
Process pressure absolute / max. overpressure limit
Any
-
Min. density of medium
Any
-
Max. measurement distance
Unlimited measuring range
Cascade -
Min. conductivity of medium
Any
-
Accuracy
+/-1%
-
Main wetted parts
Non-contact
Field of application
The Gammapilot FMG60 compact transmitter is made for non-contact point level detection, continuous level, interface and density measurement in liquids, solids, suspensions or sludges. The variable transmitter concept with NaJ crystal or plastic scintillators in different lengths guarantees optimum adaptation to individual applications. The transmitter contains a scintillator, photomultiplier and evaluation unit.
For liquids, solids, suspensions or sludges etc. Extreme measuring conditions, e.g. corrosiveness, toxicity, abrasion for all kinds of process vessels, e.g. reactors, autoclaves, separators, acid tanks, mixers, cyclones, cupola furnaces. Also for applications in food processing industry without additional requirements or approvals.
Temperature: No limitation (non-invasive)
Pressure: No limitation (non-invasive)
International explosion protection certificates, overfill prevention WHG
Benefits
Multifunctional compact transmitter: One instrument for all measuring tasks which results in cost savings in spare parts and maintenance
SIL2/3 approval in accordance with IEC 61508 for point level detection
Highest availability, reliability and safety, even for extreme process and ambient conditions
Highest sensitivity and accuracy at lowest dose rates (ALARA principle)
Aluminium or stainless steel housing 316L for heavy-duty applications
4 to 20mA output for simple plant integration
Videos
-
Radiometric measuring principle
Xpert selection
-
Specialized products
- Designed for demanding applications
Technical excellence
Simplicity
Variable

-
Standard products
- Reliable, robust and low-maintenance
Technical excellence
Simplicity
-
Specialized products
- Designed for demanding applications
Technical excellence
Simplicity
Variable
FLEX selections | Technical excellence | Simplicity |
---|---|---|
Fundamental selection Meet your basic measurement needs |
Technical excellence
|
Simplicity
|
Lean selection Handle your core processes easily |
Technical excellence
|
Simplicity
|
Extended selection Optimize your processes with innovative technologies |
Technical excellence
|
Simplicity
|
Xpert selection Master your most challenging applications |
Technical excellence
|
Simplicity
Variable |
Predecessor
-
Measuring principle
Radiometric Limit
-
Characteristic / Application
Compact transmitter
-
Specialities
Optional separate housing
-
Supply / Communication
AC: 90-253V
DC: 18-36V -
Ambient temperature
-40...60°C
(-40...140°F),
With cooling jacket:
0...120°C
(32...248°F) -
Process temperature
Any
-
Process pressure absolute / max. overpressure limit
Any
-
Min. density of medium
Any
-
Main wetted parts
Non-contact
-
Process connection
Non-contact
-
Process connection hygienic
Non-contact
-
Sensor length
PVT scintillator 200 mm (8")
PVT scintillator 400 mm (16")
NaJ scintillator 50x50mm (2") -
Communication
4...20 mA HART
FOUNDATION Fieldbus
PROFIBUS PA -
Certificates / Approvals
ATEX, FM, CSA, IEC Ex, INMETRO, JPN, NEPSI, EAC
-
Safety approvals
SIL1/ SIL2
-
Components
Isotope: FSG60, FSG61
Source container: FQG60, FQG61, FQG62, FQG63, FQG66
-
Measuring principle
Radiometric Density
-
Characteristic / Application
Compact transmitter
with PT100 input for
temperature compensation -
Supply / Communication
AC: 90-253V
DC: 18-36V -
Ambient temperature
-40°C...50°C / 60°C
With cooling jacket: 0°C...120°C -
Process temperature
Any
-
Process pressure absolute
Any
-
Wetted parts
Non-contact
-
Hygienic
Non-contact
-
Sensor length
NaJ scintillator 50x50mm
PVT scintillator 200...400mm -
Output
4-20mA HART
FOUNDATION Fieldbus
PROFIBUS PA -
Certificates / Approvals
ATEX, FM, CSA, IECEx, TIIS, NEPSI, GOST
-
Components
Isotope: FSG60
Source container: FQG60, FQG61, FQG62, FQG63, QG2000 -
Other approvals and certificates
SIL1
-
Measuring principle
Radiometric Limit
-
Characteristic / Application
Compact transmitter
-
Specialities
Interface measurement
-
Supply / Communication
DC: 90-253V
AC: 18-36V -
Ambient temperature
-40...60°C,
(-40...140°F),
With cooling jacket:
0...120°C
(32...248°F) -
Process temperature
Any
-
Process pressure absolute / max. overpressure limit
Any
-
Min. density of medium
Any
-
Min. conductivity of medium
Any
-
Main wetted parts
Non-contact
-
Process connection
Non-contact
-
Process connection hygienic
Non-contact
-
Sensor length
PVT scintillator 200 mm
PVT scintillator 400 mm
NaI scintillator 50x50mm -
Communication
4-20mA HART
FOUNDATION Fieldbus
PROFIBUS PA -
Certificates / Approvals
ATEX, FM, CSA, IEC Ex, INMETRO, JPN, NEPSI, EAC
-
Safety approvals
SIL1/ SIL2
-
Components
Isotope: FSG60, FSG61
Source container: FQG60, FQG61, FQG62, FQG63, FQG66
-
Measuring principle
Radiometric
-
Characteristic / Application
Compact transmitter
-
Specialities
Cascading for high silos
-
Supply / Communication
AC: 90-253V
DC: 18-36V -
Accuracy
+/-1%
-
Ambient temperature
-40...60°C
(-40...140°F),
With cooling jacket:
0...120°C
(32...248°F -
Process temperature
Any
-
Process pressure absolute / max. overpressure limit
Any
-
Main wetted parts
Non-contact
-
Process connection
Non-contact
-
Process connection hygienic
Non-contact
-
Sensor length
PVT scintillator
400mm...2000mm
>2000mm cascade mode -
Max. measurement distance
Unlimited measuring range
Cascade -
Communication
4...20 mA HART
FOUNDATION Fieldbus
PROFIBUS PA -
Certificates / Approvals
ATEX, FM, CSA, IEC Ex, INMETRO, JPN, NEPSI, EAC
-
Safety approvals
SIL1
-
Components
Isotope: FSG60, FSG61
Source container: FQG60, FQG61, FQG62, FQG63, FQG66
Display: FHX40
Mounting accessories: FHG60
-
Measuring principle
Radiometric
-
Characteristic / Application
Compact transmitter
Non-contact measuring technique, for extreme process conditions (temperature, pressure) -
Interface measurement
Interfaces liquid / liquid also with emulsion layers and interfaces liquid / solid
-
Specialities
Interface, density and mass flow measurement
-
Supply / Communication
AC: 90-253V
DC: 18-36V -
Accuracy
+/-1%
-
Ambient temperature
-40...60°C
(-40...140°F),
With cooling jacket:
0...120°C
(32...248°F) -
Process temperature
Any
-
Process pressure absolute / max. overpressure limit
Any
-
Main wetted parts
Non-contact
-
Process connection
Non-contact
-
Process connection hygienic
Non-contact
-
Sensor length
PVT scintillator
400mm...2000mm
>2000mm cascade mode -
Max. measurement distance
Unlimited measuring range
Cascade -
Communication
4...20 mA HART
FOUNDATION Fieldbus
PROFIBUS PA -
Certificates / Approvals
ATEX, FM, CSA, IEC Ex, INMETRO, JPN, NEPSI, EAC
-
Safety approvals
SIL1
-
Components
Isotope: FSG60, FSG61
Source container: FQG60, FQG61, FQG62, FQG63, FQG66
Display: FHX40
Mounting accessories: FHG60
Configure to download the CAD drawings of this product
Choose from our suggested options
-
-- selected coding-- selected label99.999,00<%label%>
-
Looking for more options? Please use the individual configurator to continue
-
-- selected coding-- selected label99.999,00<%feature%>
-
<%label%>99.999,00
-
Looking for more options? Please use the individual configurator to continue
-
Process Connection
-
<%label%>99.999,00
-
<%label%>99.999,00
-
-
<%feature%><%coding%><%label%>
-
Prices per piece
-
<%range%><%price%>
-
- Optional add-ons
Individual configuration
Often bought together
Accessories
Related products