Training
Proline Promag H 100
Electromagnetic flowmeter
The specialist for hygienic applications with an ultra-compact transmitter
Promag H is the preferred sensor for hygienic applications with highest requirements in the food and beverage and life sciences industries. The ultra-compact transmitter provides full performance on the smallest footprint and enables seamless system integration, making Promag H 100 the preferred choice for skid builders, equipment manufacturers and system integrators. Heartbeat Technology ensures compliance and process safety at all times.
- F
- L
- E
- X
-
Standard products
- Reliable, robust and low-maintenance
Technical excellence
Simplicity
-
Specialized products
- Designed for demanding applications
Technical excellence
Simplicity
Variable
FLEX selections | Technical excellence | Simplicity |
---|---|---|
Fundamental selection Meet your basic measurement needs |
Technical excellence
|
Simplicity
|
Lean selection Handle your core processes easily |
Technical excellence
|
Simplicity
|
Extended selection Optimize your processes with innovative technologies |
Technical excellence
|
Simplicity
|
Xpert selection Master your most challenging applications |
Technical excellence
|
Simplicity
Variable |
-
Specs at a glance
-
Max. measurement error
Volume flow (standard): ±0.5 % o.r. ± 1 mm/s (0.04 in/s)
Volume flow (option) ±0.2 % o.r. ± 2 mm/s (0.08 in/s) -
Measuring range
0.06 dm³/min to 600 m³/h (0.015 to 2650 gal/min)
-
Medium temperature range
–20 to +150 °C (–4 to +302 °F)
-
Max. process pressure
PN 40, Class 150, 20K
-
Wetted materials
Liner: PFA
Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022); Tantalum; Platinum
Process Connections: stainless steel, 1.4404 (F316L); PVDF; PVC adhesive sleeve
Seals: O-ring seal (EPDM, FKM, Kalrez), aseptic molded seal (EPDM, FKM, silicone)
Grounding Rings: stainless steel, 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022); tantalum
-
Quick selection
Individual configuration
-
Benefits
Multivariable measurement for flow, temperature and conductivity
Flexible installation concept – numerous hygienic process connections
Energy-saving flow measurement – no pressure loss due to cross-section constriction
Space-saving transmitter – full...
-
Field of application
The bidirectional measuring principle is virtually independent of pressure, density, temperature and viscosity
Dedicated to demanding applications in the food and beverage as well as in life sciences industries
Device properties
Integrated temperature...
Documents / Manuals / Software
-
Proline Promag H 100
Technical Information
Electromagnetic flowmeter
The flowmeter for smallest flow rates with an ultra-compact transmitterTechnical Information (TI) -
Proline Promag H 100
HART
Operating Instructions
Electromagnetic flowmeter
Operating Instruction (BA) -
Proline Promag H 100
PROFIBUS DP
Operating Instructions
Electromagnetic flowmeter
Operating Instruction (BA) -
Proline Promag H 100
EtherNet/IP
Operating Instructions
Electromagnetic flowmeter
Operating Instruction (BA) -
Proline Promag H 100
Modbus RS485
Operating Instructions
Electromagnetic flowmeter
Operating Instruction (BA) -
Proline Promag H 100
PROFINET
Operating Instructions
Electromagnetic flowmeter
Operating Instruction (BA) -
Proline Promag 100
HART
Description of Device Parameters
Electromagnetic flowmeter
Device Parameter (GP) -
Proline Promag 100
Modbus RS485
Description of Device Parameters
Electromagnetic flowmeter
Device Parameter (GP) -
Proline Promag 100
PROFINET
Description of Device Parameters
Electromagnetic flowmeter
Device Parameter (GP) -
Proline Promag 100
EtherNet/IP
Description of Device Parameters
Electromagnetic flowmeter
Device Parameter (GP) -
Proline Promag 100
PROFIBUS DP
Description of Device Parameters
Electromagnetic flowmeter
Device Parameter (GP) -
Proline 100
PROFINET
Brief Operating Instructions
Part 2 of 2
TransmitterShort Instruction (KA)12/15English -
Proline Promag H 100
Brief Operating Instructions
Electromagnetic flowmeter
Short Instruction (KA)09/15English -
Proline Promag
Brief Operating Instructions
Proline Promag
Part 1 of 2
Electromagnetic sensorShort Instruction (KA)04/17English -
Proline Promag H
Brief Operating Instructions
Proline Promag H
Electromagnetic sensorShort Instruction (KA)02/17English -
Activating application packages
Promag 100, 200, 400, Promass 100, 200, Prosonic Flow 100, 200, Prowirl
200, t-mass 150Installation Instructions (EA) -
Replacing Display module, non Ex, Zone 2, Class 1 Div. 2
Installation Instructions
Promass 100, Promag 100, Prosonic Flow E 100
Installation Instructions (EA) -
Replacing the Seal Housing
Installation Instructions
Promag 100, Promag 500-digital
Installation Instructions (EA) -
Replacing Transmitter
Proline Promag H, P, 100
Installation Instructions
Installation Instructions (EA) -
Replacing Small parts
Promag, Promass 100, 500, CNG-, LNG-, LPGmass, Promag 400 Index C,
Promag 800 Index C, Prosonic Flow E 100, Prosonic Flow E Heat, Pr
osonic Flow, t-mass 500-digitalInstallation Instructions (EA) -
Replacing Spare Parts
Promag, Promass 100, CNG-, LNG-, LPGmass, Promag 400 Index C, Proline
300, 500, 500-digital, Prosonic Flow E 100, Prosonic Flow E He
at, Prosonic Flow, t-mass 300, 500-digitalInstallation Instructions (EA) -
Replacing the Electronics Module
Installation Instructions
Promag 100
Installation Instructions (EA) -
Safety Instructions for Spare Parts
Installation Instructions
Flowmeter
Installation Instructions (EA) -
Proline Promag 100
ATEX:
II3G Ex nA IIC T6…T1
IECEx:
Zone 2 Ex nA IIC T6…T1
Safety Instructions
Documentation for hazardous areas
Ex Safety Instructions (XA) -
Proline Promag 100
INMETRO:
Ex nA IIC T6…T1
Safety Instructions
Documentation for hazardous area
Ex Safety Instructions (XA) -
Change of Directives
Special Documentation
Change of Directives
Special Documentation (SD) -
Proline Promag 100
Special Documentation
Heartbeat Verification + Monitoring application package
Special Documentation (SD) -
Dosimag, Promag H
Selection of the optimal nominal diameter
Special Documentation
Electromagnetic flowmeter
Special Documentation (SD) -
Proline Promag 100
HART
Web server
Special Documentation
Web server
Special Documentation (SD) -
Proline Promag 100
EtherNet/IP
Web server
Special Documentation
Web server
Special Documentation (SD) -
Proline Promag 100
Heartbeat Technology Application Package
Supplementary documentation
Electromagnetic flowmeter
Special Documentation (SD) -
Technical Documentation
Device Viewer
Special Documentation (SD) -
Information on the Pressure Equipment Directive
Proline flowmeters
Special Documentation
Proline flowmeters
Special Documentation (SD) -
Proline Promag/Promass
EtherNet/IP
System integration
Special Documentation (SD) -
Proline Promag 100
PROFINET
Web server
Special Documentation
Web server
Special Documentation (SD) -
Proline Promag 100, Promass 100
Modbus RS485
Transmitter terminal assignment
Special Documentation
Transmitter terminal assignment
Special Documentation (SD) -
Proline Promag 100
Register information Modbus RS485
Special Documentation
Electromagnetic flowmeter
Special Documentation (SD) -
Proline Promag 100
PROFIBUS DP
Web server
Special Documentation
Web server
Special Documentation (SD) -
Proline Promag 100
Manufacturer information regarding firmware updates (NE 53)
New firmware version:
Promag 100 Modbus RS485: 1.01.01Manufacturer Information (MI) -
Proline Promag 100
Manufacturer information regarding firmware
updates (NE 53)
New firmware version:
Promag 100 HART: 1.01.01Manufacturer Information (MI) -
Proline Promag 100
Manufacturer information regarding firmware
updates (NE 53)
New firmware version:
Promag 100 EtherNet/IP: 1.01.01Manufacturer Information (MI) -
Proline Promag 100
Manufacturer information regarding firmware
updates (NE 53)
New firmware version:
Promag 100 PROFIBUS DP: 1.01.01Manufacturer Information (MI) -
Trait d'union 56 - Edition Agroalimentaire
Le Journal d'Information Endress+Hauser France
Customer Magazine (CM)06/13fr -
Industrial Ethernet for Proline flowmeters
The system integration of the future
Innovations (IN)12/17English -
Industrial Ethernet für Proline Durchflussmessgeräte
Die Systemintegration der Zukunft
Innovations (IN)12/17German -
Proline Promass 100 / Promag 100
Der Durchfluss-Spezialist im Kompaktdesign
Volle Funktionalität auf engstem RaumInnovations (IN)11/14German -
Proline Promass 100 / Promag 100
The flow specialists in a compact design
Full functionality in a small packageInnovations (IN)11/14English -
Ethernet industriel pour débitmètres Proline
L'intégration système du futur
Innovations (IN)10/15fr -
Proline Promass 100 / Promag 100
Zaawansowane możliwości w kompaktowym wydaniu.
Rodzina kompaktowych przepływomierzy masowych
i elektromagnetycznychInnovations (IN)06/12Polish -
GSD Single, GSD_PN_FL_Promag100_0x843A_0x01_0x02, 11.08.2020 (Flow, Promag 100, 0x843A)
PROFINET,
PROFINET System Version: AnyGeneral Station Description (GSD)1.00.01Language neutral -
GSD Single, GSD_DP_FL_Promag100_0x1560_0x01_0x01, 14.04.2014 (Flow, Proma
g 100, 0x1560)
PROFIBUS DP,
PROFIBUS System Version: AnyGeneral Station Description (GSD)1.00.00Language neutral -
GSD Single, GSD_DP_FL_Promag100_0x1560_0x02_0x01, 30.06.2015 (Flow, Proma
g 100)
PROFIBUS DP,
PROFIBUS System Version: AnyGeneral Station Description (GSD)1.00.00Language neutral -
EDS Single, EDS_EH_EIP_FL_Promag_100_0x103A_0x02_0x01, 23.10.2015 (Flow, Promag 100)
EtherNet/IP,
EtherNet IP System Version: AnyElectronic Data Sheet (EDS)2.1Language neutral -
EDS Single, EDS_EH_EIP_FL_Promag_100_0x103A_0x01_0x01, 23.10.2015 (Flow,
Promag 100)
EtherNet/IP,
EtherNet IP System Version: AnyElectronic Data Sheet (EDS)1.1Language neutral -
EDD Single, PDM_DP_FL_Promag100_0x1560_0x01_0x01, 28.03.2014 (Flow, Proma
g 100, 0x1560)
PROFIBUS DP,
PDM Version: 6.1, 8.1Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_DP_FL_Promag100_0x1560_0x02_0x01, 17.06.2015 (Flow, Proma
g 100)
PROFIBUS DP,
PDM Version: 6.1, 8.2Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_HART_FL_Promag100_0x003A_0x01_0x01, 31.03.2014 (Flow, Pro
mag 100, 0x003A)
HART,
PDM Version: 6.1, 8.0.2Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS12_HART_FL_Promag100_0x003A_0x02_0x01, 20.08.2019 (Flow, Promag 100, 0x003A)
HART,
AMS Version: 12.0, 12.5, 13.0, 13.1, 13.5Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_HART_FL_Promag100_0x003A_0x02_0x01, 16.03.2015 (Flow, Promag 100, 0x003A)
HART,
PDM Version: 6.1, 8.1 SP1Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS12_HART_FL_Promag100_0x003A_0x01_0x01, 20.08.2019 (Flow, Promag 100, 0x003A)
HART,
AMS Version: 12.0, 12.5, 13.0, 13.1, 13.5Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS11_HART_FL_Promag100_0x003A_0x01_0x01, 20.08.2019 (Flow, Promag 100, 0x003A)
HART,
AMS Version: 10.5, 11.0, 11.1, 11.5, 12.0Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, FDM_HART_FL_Promag100_0x003A_0x01_0x01, 31.03.2014 (Flow, Pro
mag 100, 0x003A)
HART,
Field Device Manager Version: R410Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS11_HART_FL_Promag100_0x003A_0x02_0x01, 20.08.2019 (Flow, Promag 100, 0x003A)
HART,
AMS Version: 10.5, 11.0, 11.1, 11.5, 12.0Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, FDM_HART_FL_Promag100_0x003A_0x02_0x01, 16.03.2015 (Flow, Promag 100, 0x003A)
HART,
Field Device Manager Version: R430.1Electronic Data Description (EDD)1.00.00Language neutral -
DTM Single, Promag100_5x1B_DP_FW1_01_zz_Dev_Rev_2, 19.10.2020 (Flow, Promag 100, 0x1560)
PROFIBUS DP,
DeviceCare Version: 1.07.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.7.0.86Language neutral -
DTM Single, Promag100_5x1B_PNIO-CDIE_FW_1_00_zz_Dev_Rev_1, 05.11.2020 (Flow, Promag 100, 0x843A)
PROFINET,
DeviceCare Version: 1.06.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.6.0.37Language neutral -
DTM Single, Promag_100_5x1B_EIP_FW_1_01_zz_Dev_Rev_2, 05.11.2020 (Flow, Promag 100, 0x103A)
EtherNet/IP,
DeviceCare Version: 1.06.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.6.0.175Language neutral -
DTM Single, Promag_100_5x1B_EIP-CDIE_FW_1_01_zz_Dev_Rev_2, 05.11.2020 (Flow, Promag 100)
EtherNet/IP,
DeviceCare Version: 1.06.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.5.0.174Language neutral -
DTM Single, Promag_100_5x1B_MR4_FW_1_01_zz_Dev_Rev_2, 06.11.2020 (Flow, Promag 100, 0x643A)
Modbus RS485,
DeviceCare Version: 1.07.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.4.1.354Language neutral -
DTM Single, Promag_100_5x1B_MR4-CDIS_FW_1_01_zz_Dev_Rev_2, 06.11.2020 (Flow, Promag 100, 0x643A)
Modbus RS485,
DeviceCare Version: 1.07.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.4.1.354Language neutral -
DTM Single, Promag100_5x1B_HART_FW1_01_zz_Dev_Rev_02, 27.10.2020 (Flow, Promag 100, 0x113A)
HART,
DeviceCare Version: 1.07.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.3.0.201Language neutral -
DTM Single, Promag100_5x1Bxx_DP_FW1_00_zz_Dev_Rev_1, 19.10.2020 (Flow, Promag 100, 0x1560)
PROFIBUS DP,
DeviceCare Version: 1.07.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.1.0.55Language neutral -
DTM Single, Promag_100_5x1B_MR4_FW_1_00_zz_Dev_Rev_1, 06.11.2020 (Flow, Promag 100, 0x643A)
Modbus RS485,
DeviceCare Version: 1.07.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.0.0.300Language neutral -
DTM Single, Promag100_5x1B_HART_FW1_00_zz_Dev_Rev_01, 23.10.2020 (Flow, Promag 100, 0x003A)
HART,
DeviceCare Version: 1.07.00
Field Device Manager Version: R430.1
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00
FieldMate Version: 2.05
Plant Resource Manager Version: R3.10Device Type Manager (DTM)1.0.0.161Language neutral -
DTM Single, Promag_100_5x1B_EIP_FW_1_00_zz_Dev_Rev_1, 05.11.2020 (Flow, Promag 100, 0x103A)
EtherNet/IP,
DeviceCare Version: 1.06.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.0.0.135Language neutral -
AOP Single, RS_EIP_FL_Promag100_5x1B_0x103A_0x02_0x01, 10.02.2021 (Flow, Promag 100, 0x103A)
EtherNet/IP,
RA RSLogix 5000 Version: V15 and laterAdd On Profile (AOP)1.66.01Language neutral -
Faceplate Library, PRM_HART_Package_Flow_1_08_00, 22.07.2015 (Flow)
HART,
Plant Resource Manager Version: R3.02, R3.05, R3.10, R3.11, R3.12Faceplate1.08.00Language neutral -
Faceplate Single, PRM_HART_FL_Promag100_0x003A_0x02_0x01, 16.03.2015 (Flow, Promag 100, 0x003A)
HART,
Plant Resource Manager Version: R3.11Faceplate1.00.00Language neutral -
Faceplate Single, PRM_HART_FL_Promag100_0x003A_0x01_0x01, 31.03.2014 (Flo
w, Promag 100, 0x003A)
HART,
Plant Resource Manager Version: R3.10Faceplate1.00.00Language neutral -
Note Single, Release_Notes_for_AMS_HART_Flow, 15.06.2018 (Flow)
HART,
AMS Version: AnyNote1.00.00Language neutral -
Verification DTM Library, VerificationDTM_FLOW_HART, 15.05.2020 (Flow)
HART,
DeviceCare Version: 1.06.00
FieldCare Version: 2.13.00Verification DTM1.06.05Language neutral -
Verification DTM Library, VerificationDTM_FLOW_EIP, 15.05.2020 (Flow)
EtherNet/IP,
DeviceCare Version: 1.06.00
FieldCare Version: 2.13.00Verification DTM1.06.05Language neutral -
Verification DTM Library, VerificationDTM_FLOW_ProfiNet, 15.05.2020 (Flow)
PROFINET,
DeviceCare Version: 1.06.00
FieldCare Version: 2.13.00Verification DTM1.06.05Language neutral -
Verification DTM Library, VerificationDTM_FLOW_Modbus_RS485, 15.05.2020 (Flow)
Modbus RS485,
DeviceCare Version: 1.06.00
FieldCare Version: 2.13.00Verification DTM1.06.05Language neutral -
Verification DTM Library, VerificationDTM_FLOW_PROFIBUS_DP, 15.05.2020 (Flow)
PROFIBUS DP,
DeviceCare Version: 1.06.00
FieldCare Version: 2.13.00Verification DTM1.06.05Language neutral -
Dosimag, Dosimag OEM, Promag 10, Promag 50, Promag 53, Promag 55, Promag H
Product Code: DDA-, 5SH-, 5RH-, 5HBB-, 5H5B-, 5H3B-, 5H2B-, 5H1B-, 5DH-, 5CH-, 5BH-, 55H-, 53H-, 50H-, 10H-
Declaration Number: HE_01001_04.18
Manufacturer Specification: Food hygieneManufacturer DeclarationGerman , English -
Promag P, Promag H, Promag E, Promag 55, Promag 53, Promag 50, Promag 10, Ersatzteil, Dosimag OEM, Dosimag
Product Code: 5P5B-, 5P3B-, 5H5B-, 5H3B-, 5P1B-, 5H1B-, 53H-, 53P-, 50H-, 5P2B-, 5H2B-, 50P-, 55S-, 55H-, O5H1B-, DKH-, DK5HB-, DK5G-, 5SH-, 5RH-, 5CH-, 5BH-, 5DH-, 10H-
Declaration Number: HE_01074_01.18Manufacturer DeclarationGerman , English -
Dosimag OEM, Ersatzteil, Promag 10, Promag 50, Promag 53, Promag 55, Promag H
Product Code: O5H2B-, O5H1B-, DKH-, DK5HB-, DK5G-, 5SH-, 5RH-, 5HBB-, 5H5B-, 5H3B-, 5H2B-, 5H1B-, 5DH-, 5CH-, 5BH-, 55H-, 53H-, 50H-, 10H-
Declaration Number: HE_00404_05.17
Manufacturer Specification: Food hygiene, 1935/2004Manufacturer DeclarationGerman , English -
Dosimag, Dosimag OEM, Ersatzteil, Promag 10, Promag 50, Promag 53, Promag 55, Promag H, Promag P
Product Code: 5P1B-, 5P2B-, 5P3B-, 5P5B-, 5RH-, 5SH-, DDA-, DK5G-, DK5HA-, DK5HB-, DKH-, O5H1B-, O5H2B-, O5P1B-, O5P2B-, 5H5B-, 5H3B-, 5H2B-, 5H1B-, 5H-, 5DH-, 5CH-, 5BH-, 55S-, 55H-, 53P-, 53H-, 50P-, 50H-, 10P-, 10H-
Declaration Number: FDA_00131_04.17FDA DeclarationGerman , English -
Dosimag OEM, Promag 10, Promag 50, Promag 53, Promag 55, Promag H
Product Code: O5H1B-, 5SH-, 5RH-, 5H5B-, 5H3B-, 5H2B-, 5H1B-, 5DH-, 5CH-, 5BH-, 55H-, 53H-, 50H-, 10H-
Declaration Number: EC_00714_03.18EU DeclarationGerman , English -
Promag E, Promag H, Promag P
Product Code: 5E1B-, 5H1B-, 5P1B-
Declaration Number: EC_00281_01.16EU DeclarationGerman , English , fr -
Promag H
Product Code: 5H1B-, 5H3B-, 5H5B-, O5H1B-
Declaration Number: EC_00280_03.16EU DeclarationGerman , English , fr -
Dosimag OEM, Promag H, Promag 10, Promag 50, Promag 53, Promag 55
Product Code: O5H1B-, 5H5B-, 5H1B-, 5H3B-, 50H-, 53H-, 55H-, 5H2B-, 5SH-, 5RH-, 5DH-, 5CH-, 5BH-, 10H-
Declaration Number: EC_00714_02.18EU DeclarationGerman , English -
Dosimag OEM, Promag 10, Promag 50, Promag 53, Promag 55, Promag H
Product Code: O5H1B-, 5SH-, 5RH-, 5H5B-, 5H3B-, 5H2B-, 5H1B-, 5DH-, 5CH-, 5BH-, 55H-, 53H-, 50H-, 10H-, 5HBB-
Declaration Number: EC_00714_04.18EU DeclarationGerman , English -
Promag E, Promag H, Promag P
Product Code: 5E1B-, 5H1B-, 5P1B-
Declaration Number: EC_00282_02.16EU DeclarationGerman , English , fr -
Promag W, Promag P, Promag L, Promag H, Promag E, Promag D, Promag 55, Promag 53, Promag 51, Promag 50, Promag 10, Dosimag
Product Code: 55S-, 5D4B-, 5D4C-, 5E1B-, 5H-, 5H1B-, 5H3B-, 5H5B-, 5L4B-, 5L4C-, 5P1B-, 5P3B-, 5P5B-, 5W3B-, 5W4D-, 5W5B-, 5W8B-, 5W8C-, DDA-, 55H-, 53W-, 53P-, 53L-, 53H-, 53E-, 51W-, 51P-, 50W-, 50P-, 50L-, 50H-, 50E-, 50D-, 10W-, 10P-, 10L-, 10H-, 10E-, 10D-
Region/Country: Russia (TR CU)
Approval Agency: EAC
Approval Number: EAEC N RU D-CH.AD07.B.02228/20MiscellaneousRussian -
Promass K, Promass O, Promass P, Promass Q, Promass S, Promass X, Prosonic Flow 91, Prosonic Flow 92, Prosonic Flow 93, Prosonic Flow G, Prowirl D, Prowirl F, Prowirl O, Prowirl R, t-mass, t-mass A, t-mass B, T-MASS F, T-MASS I, Promass I, CNGmass, Dosimag, Dosimass, LNGmass, LPGmass, Promag 10, Promag D, Promag E, Promag H, Promag L, Promag P, Promag W, Promass 40, Promass 80, Promass 83, Promass 84, Promass E, Promass F, Promass H
Product Code: 8I3B-, 8I1B-, 8H5B-, 8H3B-, 8F5B-, 8F3B-, 8F2B-, 8F1B-, 8E5B-, 8E3B-, 8E2C-, 8E2B-, 8E1C-, 8E1B-, 8E-, 84X-, 84F-, 83X-, 83F-, 80F-, 7R2C-, 8I5B-, 8K1B-, 8O3B-, 8O5B-, 8P1B-, 8P3B-, 8P5B-, 8Q3B-, 8Q5B-, 8S1B-, 8S1C-, 8S3B-, 8S5B-, 8X3B-, 8X5B-, 91W-, 92F-, 93C-, 93W-, 9G3B-, 9G5B-, DDA-, 7R2B-, 10D-, 10E-, 10H-, 10L-, 10P-, 10W-, 40E-, 5D4B-, 5D4C-, 5E1B-, 5E2B-, 5H-, 5H1B-, 5H2B-, 5H3B-, 5H5B-, 5L4B-, 5L4C-, 5P1B-, 5P2B-, 5P3B-, 5P5B-, 7O2C-, 7O2B-, 7F2C-, 7F2B-, 7D2C-, 7D2B-, 6I5B-, 6I3B-, 6F5B-, 6F3B-, 6BAB-, 6AAB-, 65I-, 65F-, 5W8C-, 5W8B-, 5W5B-, 5W4D-, 5W4C-, 5W4B-, 5W3B-
Region/Country: Russia (TR CU)
Approval Agency: EAC
Approval Number: EAEC N RU D-CH.AD07.B.03271/20MiscellaneousRussian -
Promag W, Promag P, Promag L, Promag H, Promag E, Promag D, Promag 55, Promag 53, Promag 51, Promag 50, Promag 10, Dosimag, Promass X, Promass S, Promass Q, Promass P, Promass O, Promass I, Promass H, Promass F, Promass E, Promass A, Promass 84, Promass 83, Promass 80, Dosimass OEM
Product Code: 5D4C-, 5P5B-, 5W5B-, 5P3B-, 5H5B-, 5W3B-, 5W4C-, 5L4C-, 53P-, 53W-, 5P1B-, 5H1B-, 5H3B-, 50W-, 50P-, 50H-, 53H-, 5E1B-, 55S-, 5P2B-, 53L-, 55H-, 5H2B-, 50L-, 53E-, 50D-, 50E-, 51W-, 5H-, 5L4B-, 5W4D-, 5W4B-, 5W8B-, 5W8C-, DDA-, 5D4B-, 10D-, 10E-, 10H-, 10P-, 10W-, 10L-, 51P-, 8E5B-, 8F1B-, 8F2B-, 8F3B-, 8H1B-, 8H3B-, 8H5B-, 8I1B-, 8I3B-, 8I5B-, 8O1B-, 8O3B-, 8P1B-, 8P3B-, 8P5B-, 8Q3B-, 8Q5B-, 8S1B-, 8S3B-, 8S5B-, 8X3B-, 8X5B-, 80A-, 80E-, 80F-, 80I-, 80P-, 80S-, 83A-, 83E-, 83F-, 83H-, 83I-, 83P-, 83S-, 83X-, 84F-, 84X-, 8A1B-, 8A3B-, 8A5B-, 8BE-, 8E1B-, 8E2B-, 8E3B-
Region/Country: Russia (TR CU)
Approval Agency: EAC
Approval Number: EAEC N RU D-CH.AD07.B.02246/20MiscellaneousRussian -
Dosimag, Promag 10, Promag D, Promag E, Promag H, Promag L, Promag P, Promag W
Product Code: 5H3B-, 5H5B-, 5L4B-, 5L4C-, 5P1B-, 5P2B-, 5P3B-, 5P5B-, 5W3B-, 5W4B-, 5W4C-, 5W5B-, 5H2B-, 5H1B-, 5H-, 5E2B-, 5E1B-, 5D4C-, 5D4B-, 10W-, 10P-, 10L-, 10H-, 10E-, 10D-
Region/Country: Russia (TR CU)
Approval Number: EAEC N RU D-CH.AD07.B.03271/20MiscellaneousRussian -
Promag 10, Promag 50, Promag 51, Promag 53, Promag D, Promag E, Promag H, Promag L, Promag P, Promag W
Product Code: 53L-, 53P-, 53W-, 5D4B-, 5D4C-, 5E1B-, 5E2B-, 5H1B-, 5H2B-, 5L4B-, 5L4C-, 5P1B-, 5P2B-, 5W4B-, 5W4C-, 5W8B-, 53H-, 53E-, 51W-, 51P-, 50W-, 50P-, 50L-, 50H-, 50E-, 50D-, 10W-, 10P-, 10L-, 10H-, 10E-, 10D-
Region/Country: Russia (TR CU)
Approval Agency: EAC
Approval Number: TC BY_112 11.01. TP020 003 126MiscellaneousRussian -
Promag D, Promag E, Promag H, Promag L, Promag P, Promag W
Product Code: 5E1B-, 5H1B-, 5P1B-, O5E1B-, O5H1B-, O5P1B-
Region/Country: Canada, USA
Approval Agency: CSA
Category: I/2/A,B,C,D, I/zone 2
Protection: AEx/Ex nA IIC T6...T1 GcExplosion ProtectionEnglish -
Promag P, Promag H, Promag W, Promag D, Promag E, Promag L
Product Code: 5P1B-, 5E1B-, 5H1B-, O5E1B-, O5H1B-, O5P1B-
Region/Country: Canada, USA
Approval Agency: CSA
Category: I/2/A,B,C,D, I/zone 2
Protection: AEx/Ex nA IICExplosion ProtectionEnglish -
Promag E, Promag H, Promag L, Promag P, Promag W
Product Code: O5W1B-, O5P1B-, O5L1B-, O5H1B-, O5E1B-, 5W1B-, 5P1B-, 5L1B-, 5H1B-, 5E1B-
Region/Country: Brazil
Approval Agency: INMETRO
Category: zone 2
Protection: Ex nAExplosion ProtectionEnglish -
Promag E, Promag P, Promag W, Promag H, Promag L
Product Code: O5W1B-, 5P1B-, 5H1B-, 5E1B-, O5P1B-, O5L1B-, O5H1B-, O5E1B-, 5W1B-, 5L1B-
Region/Country: Europe, International (IECEx)
Approval Agency: DEKRA
Protection: Ex nAExplosion ProtectionEnglish -
Dosimag, Promag H, Dosimag OEM, Promag 10, Promag 23, Promag 50, Promag 53, Promag 55
Product Code: O5H2B-, 5H5B-, 5H1B-, 5H3B-, 50H-, 53H-, 5H2B-, 55H-, O5H1B-, DDA-, 5SH-, 5RH-, 5H-, 5DH-, 5CH-, 5BH-, 23H-, 10H-
Region/Country: International
Approval Agency: DTUHygienic EquipmentEnglish -
Promag H
Product Code: 5H1B-, 5H3B-, 5H5B-
Region/Country: USA
Approval Agency: 3-A Sanitary StandardsHygienic EquipmentEnglish -
Promag E, Promag H, Promag P
Product Code: 5E1B-, 5H1B-, 5P1B-
Region/Country: International
Approval Agency: FieldComm GroupFieldbus ConformanceEnglish -
Promag E, Promag P, Promag H
Product Code: 5E1B-, 5P1B-, 5H1B-
Region/Country: International
Approval Agency: PI, PROFIBUS International
Software Version: 1.00.01Fieldbus ConformanceEnglish -
Promag E, Promag P, Promag H
Product Code: 5H1B-, 5P1B-, 5E1B-
Region/Country: International
Approval Agency: PI, PROFIBUS International
Software Version: PROFIBUS PA PROFILE 3.0.2Fieldbus ConformanceEnglish -
Promag E, Promag H, Promag P
Product Code: 5E1B-, 5H1B-, 5P1B-
Region/Country: International
Approval Agency: ODVAFieldbus ConformanceEnglish -
Promag W, Promag P, Promag L, Promag H, Promag E, Promag D, Promag 55, Promag 53, Promag 51, Promag 50, Promag 10
Product Code: 55S-, 5D4B-, 5D4C-, 5E1B-, 5H1B-, 5H2B-, 5H3B-, 5H5B-, 5L4B-, 5L4C-, 5P1B-, 5P2B-, 5P3B-, 5P5B-, 5W4B-, 5W4C-, 5W5B-, 5W8B-, 55H-, 53W-, 53P-, 53L-, 53H-, 53E-, 51W-, 51P-, 50W-, 50P-, 50L-, 50H-, 50E-, 10W-, 10P-, 10L-, 10H-, 10E-, 10D-
Region/Country: Uzbekistan
Approval Agency: UZS
Approval Number: 02.6720MetrologyRussian -
Dosimag OEM, Promag 53, Promag H, Promag P, Promag W
Product Code: 5W5B-, 5W3B-, 5P5B-, 5P3B-, 5P1B-, 5H5B-, 5H3B-, 5H1B-, 5BH-, 53W-, 53P-, 53H-
Region/Country: USA
Approval Agency: NTEP
Approval Number: NTEP 06-019MetrologyEnglish -
Promag D, Promag P, Promag W, Promag H, Promag L, Promag E
Product Code: 5W8B-, 5W4C-, 5L4C-, 5P1B-, 5H1B-, 5H3B-, 5E1B-, 5P2B-, 5D4C-, 5H2B-, 5W4B-, 5L4B-, 5E2B-, 5D4B-
Region/Country: Russia
Approval Agency: Rosstandart
Approval Number: CH.C.29.004.А NO. 59660/1MetrologyRussian -
Promag H, Promag P, Promag W
Product Code: 5H1B-, 5H3B-, 5H5B-, 5P3B-, 5P5B-, 5W3B-, 5W5B-
Region/Country: International
Approval Agency: RM RSMarineRussian -
Promag H, Promag P, Promag W
Product Code: 5H1B-, 5H3B-, 5H5B-, 5P1B-, 5P3B-, 5P5B-, 5W3B-, 5W5B-
Region/Country: International
Approval Agency: CCSMarineEnglish -
Promag H, Promag P
Product Code: 5H1B-, 5P1B-
Region/Country: International
Approval Agency: ABSMarineEnglish -
Promag H
Product Code: 5H1B-
Region/Country: International
Approval Agency: BVMarineEnglish -
Promag H
Product Code: 5H1B-
Region/Country: International
Approval Agency: DNVGLMarineEnglish -
Promag H, Promag P, Promag W
Product Code: 5H3B-, 5H5B-, 5P3B-, 5P5B-, 5W3B-, 5W5B-, 5H1B-
Region/Country: International
Approval Agency: LRMarineEnglish -
Promag H
Product Code: 5H1B-
Region/Country: USA
Approval Agency: FDAFood SafetyEnglish -
Promag E, Promag H, Promag P
Product Code: 5E1B-, 5H1B-, 5P1B-
Region/Country: Germany
Approval Agency: TÜV
Approval Number: PC/209/03/144/11-12/15Heartbeat TechnologyGerman , English
Accessories / Spare parts
-
-
Nr 39 Order code 71185788
Kit T-DAT, 100/300/400/500/500 digital
Usage: Promag/Promass 100/300/500, 500 digital, Prosonic Flow E 100, Prosonic Flow/t-mass 300, 500 digital, Promag 400(C). (C) = generation index C.
-
-
-
Nr 30 Order code XPD0010-
-
-
-
Nr 50 Order code XPD0023-
Display module, 4-wire, 100
Usage: Promag 100, Promass 100, Prosonic Flow E 100.
-
-
-
Nr 21 Order code 71185789
Kit cover, compact, Alu
Usage: Promass 100, Promag 100, Prosonic Flow E 100/E Heat, CNGmass, LPGmass, LNGmass. Consists of: Cover Aluminium, coated. O-Ring 113,90 x 3,53 NBR for cover.
-
Nr 21 Order code 71185790
Kit cover, compact, stainless 1.4301
Usage: Promass 100, Promag 100, Prosonic Flow 100. Consists of: Cover stainless 1.4301. Gasket EPDM for cover.
-
Nr 21 Order code 71185793
Kit cover,ultra compact,stainless 1.4301
Usage: Promag/Promass 100, Promag/Promass 500 digital, sensor connection housing. Consists of: cover stainless 1.4301, gasket EPDM for cover.
-
-
-
Nr 20 Order code 71266334
Kit cover, sight glass, compact, Alu
Usage: Promass 100, Promag 100, Prosonic Flow E 100/E Heat. Consists of: Cover with sight glass Aluminium, coated. O-Ring 113,90 x 3,53 NBR for cover.
-
Nr 20 Order code 71266335
Kit cover, sight glass, compact, 1.4301
Usage: Promass 100, Promag 100, Prosonic Flow 100. Consists of: Cover with sight glass stainless 1.4301. Gasket EPDM for cover.
-
Nr 20 Order code 71266337
Kit cover,sight glass,ultra comp.,1.4301
Usage: Promass 100, Promag 100. Consists of: Cover with sight glass stainless 1.4301. Gasket EPDM for cover.
-
-
-
Nr 70 Order code 71211571
Kit housing gaskets, compact, Alu
Usage: Promag 100. Consists of: O-Ring 113,90 x 3,53 NBR for cover. Gasket EPDM for housing/sensor H. Gasket EPDM for housing/sensor E/P. O-Ring 29,87 x 1,78 HNBR for sensor connector.
-
Nr 70 Order code 71211572
Kit housing gaskets, compact, stainless
Usage: Promag 100. Consists of: Gasket EPDM for cover. Gasket EPDM for housing/sensor H. O-Ring 29,87 x 1,78 HNBR for sensor connector.
-
Nr 70 Order code 71211573
Kit hous.gaskets,ultra compact,stainless
Usage: Promag 100, Promag 500 digital, sensor connection housing. Consists of: gasket EPDM for cover, gasket EPDM for housing/sensor H, O-Ring 29,87x1,78 HNBR for sensor plug.
-
-
-
Nr 15 Order code 50098036
Kit 10 cable glands M20x1.5 Ex
-
Nr 15 Order code 71069285
Kit 2 cable glands M20x1.5 INOX Ex
-
Nr 15 Order code 50098041
Kit 10 ext. M20x1.5/G 1/2" (plug PVC)
-
Nr 15 Order code 71185802
Kit 2 cable glands G1/2" INOX Ex
Consists of: 2 x Extension M20x1,5/G1/2" 1.4404. 2 x O-Ring. 2 x Sealing plug G1/2".
-
Nr 15 Order code 50098042
Kit 10 ext. M20x1.5/NPT 1/2" (plug PVC)
-
Nr 15 Order code 71185800
Kit 2 cable glands NPT1/2" INOX Ex
Consists of: 2 x Extension M20x1,5/NPT1/2" 1.4404. 2 x O-Ring. 2 x Sealing plug NPT1/2".
-
-
-
Nr 12 Order code 71276494
Kit securing clamp, screw
Usage: Promass 100, Promag 100, Prosonic Flow E 100/E Heat, CNGmass, LPGmass, LNGmass. Sensor housing: Promag 400(C), (C) = generation index C, Promag/Promass 500, Promag/Promass/Prosonic Flow/t-mass 500 digital. Consists of: cover clamp, screw M4x16.
-
-
-
Order code DKH-
Promag H, mounting set
A mounting set includes 2 process connections incl. screws and the corresponding seals.
-
Order code DK5G-
Promag H/Dosimag, seal set
-
Order code DK5HB-
Promag H, distance disc
The set includes 2 distance discs incl. screws and 2 seals. For dimensions refer to the technical documentation.
-
Order code DK5HM-
Promag H, wall mounting set
-
Order code DK5HW-
Promag H, weld in tool
-
Order code DK5HA-
Promag H, adapter set
Replacement of sensor Promag A or Promag H DN 25. The set includes 2 adapters and 2 seals. For dimensions refer to the technical documentation.
-
Order code DK5HR-
-
Order code XPRFID-
-
-
Predecessor